Inspection wear limits – GEARENCH BDA100 PETOL Tubing Elevator User Manual

Page 9

Advertising
background image

7

Inspection Wear Limits


Link Support Arm

• Nominal Arm Thickness – 3.000” (from contact area to top of body)
• Minimum Arm Thickness after wear – 2.938”


Bore (measured with bodies wedged apart to remove all slack in components)

1. BDA100-238N – 2.512” (maximum localized length = 0.594)
2. BDA100-238U – 2.764” (maximum localized length = 0.648)
3. BDA100-278N – 3.013” (maximum localized length = 0.718)
4. BDA100-278U – 3.264” (maximum localized length = 0.773)
5. BDA100-312N – 3.639” (maximum localized length = 0.875)
6. BDA100-312U – 3.920” (maximum localized length = 0.937)

If localized portions of the bore are found to measure larger than the maximum bore
allowance tabulated above, the bore need not be rejected provided that all of the
following conditions are met:

a) The depth of wear, grinding, or other damage in the localized portion(s) of the

bore shall not exceed 1/8 inch (3.2 mm).

b) The surface of all localized wear, grinding, or other damage, shall be blended back

to the adjacent bore surface with a transition not less than a ratio of 3 to 1 (length
to depth).

c) After blending, the total length (measured around the bore surface) of all such

areas of localized wear, grinding, etc., including transitions to the bore surface
shall not exceed the maximum length shown above.


Hinge Pin

• Diameter – 1.739”


Hinge Pin Hole (In the Right and Left Bodies)

• Diameter – 1.763”


Retainer Pin

• Diameter – 0.740”


Retainer Pin Hole (In the Left Body and the Retainer)

• Diameter – 0.763”


Lock Pin

• Diameter – 0.491”


Lock Pin Hole (In the Retainer and the Lock)

• Diameter – 0.513”

Advertising