Use on couplings – GEARENCH SCT2036 PETOL SURGRIP Casing Tong User Manual

Page 12

Advertising
background image

10

With heavy duty belts (0.250 inch thick, 31 cords wide)



Diameter

Belt

Part

Number

Torque

Arm

Length

(inches)

Maximum

Torque

(foot-pounds)

Maximum

Line Pull

(pounds)

18

SCTB2036-18H

45.65

105,400

27,700

18 3/8

SCTB2036-1838H

45.83

106,600

27,900

18 5/8

SCTB2036-1858H

45.95

107,600

28,100

20

SCTB2036-20H

46.62

111,900

28,800

22

SCTB2036-22H

47.60

118,200

29,800

24

SCTB2036-24H

48.56

123,800

30,600

26

SCTB2036-26H

49.54

129,600

31,400

28

SCTB2036-28H

50.51

135,100

32,100

30

SCTB2036-30H

51.48

140,300

32,700

32

SCTB2036-32H

52.46

145,600

33,300

32 1/4

SCTB2036-3214H

52.58

145,900

33,300

32 1/2

SCTB2036-3212H

52.70

146,700

33,400

36

SCTB2036-36H

54.40

155,000

34,200

38

SCTB2036-38H

55.38

159,700

34,600



WARNING: Under no circumstances should the maximum working load be
exceeded. Always use a load cell or other calibrated indicating device to monitor
the line pull on the tong to avoid an overload.

Use on couplings

The yoke plates attached to the handle have three holes. One hole is used to fix the belt to the
yoke plates. One hole is marked “PIPE”, when this hole is fixed to the handle, the tong will
latch on the pipe for the appropriate belt. The third hole is marked “COUPLING”, this hole
will allow the tong to be latched onto a coupling with a diameter of one inch over the pipe
diameter.