Installation – GEARENCH U118-000-G PETOL HYDRA-TORK User Manual

Page 14

Advertising
background image

14

Installation

Location

The Petol Hydra-Tork Unit should be located in an area with adequate room to work the
downhole tools. The unit may be located indoors or outdoors upon solid level ground or a
finished shop floor. No special foundation is required.

Setup

Locate the hydraulic console in a convenient location and connect the hoses to the hydraulic
cylinder.

Startup

Check that the engine has the appropriate amounts of lubricating oil and gasoline prior to
starting. Please read the Briggs & Stratton owner’s manual prior to use.

The unit is shipped with the starting battery disconnected. The battery is located inside the
main cabinet of the console. Remove the rear cover and connect the battery prior to starting.

Verify that the hydraulic oil level is within the operating limits as shown on the console sight
glass. Use Chevron AW-ISO46 or equal (20 gallons). Start the hydraulic pump. If the
cylinder will only extend and not retract (1) turn off the engine; (2) reverse the hoses
attaching the console to the cylinder.

Cycle the cylinder several times to clear the system of any entrapped air.


Advertising