IMP Pumps NMT(D) 40-100 & NMT SAN flanges User Manual

Page 24

Advertising
background image

GB

-24-

5.6.2.1

O

verview

(web page OVERVIEW)

Displays pump operation summary, like:

Power consumption,

Grid current,

RPM,

Estimated head,

Estimated flow,

Estimated efficiency,

Motor status,

Heatsink temperature,

Statistics,

Remote control.

5.6.2.2 p

ump

settings

(Web page PUMP)

Page is meant to provide regulation settings.

“Limit head to” will set maximum allowable head.

“Hmax proportional to Q” will set the ratio between head and flow.

o

Hmax = 0%: constant pressure is set and should not exhibit noticeable change

until maximum power is reached.

o

Hmax = X%: parameter will set the percentage of drop in head from maximum to

closed valve.

“Limit rpm to”: will limit motor speed

“Limit power to”,

“Limit grid current to”,

“Limit heatsink temperature to”.

Switch on the relay when:

o

0: no function.

o

OPERATION: pump ready to operate.

o

RUN: pump operating.

o

ERROR: error detected.

Input I1 is:

o

0: no function.

o

DUPLEX: twin connection.

o

RUN: remote start.

o

MAX: maximum head.

o

EXTERNAL: external pressure switch.

o

Input I2 has functions the same as I1.

SAVE: will write settings in permanent memory,

TEST: Will use settings but will not save them. Restart will restore previous settings as will

pressing »RESTORE« button.

5.6.2.3

n

etwOrk

settings

(Web page NETWORK): Provides a way to change network configuration.

Buttons operate in a similar manner as on previous page.

5.6.2.4

l

oG

(Web page LOG)

Page will display possible errors and some unusual events.