AAEON IMBA-Q87A User Manual

Page 41

Advertising
background image

3-9

Chapter 3: BIOS setup

Fan Control Mode [Thermal Cruise Mode]
Configuration options: [Manual Mode] [Thermal Cruise Mode] [Speed Cruise

Mode] [Smart Fan IV Mode]

The following items appear only when you set Fan Control Mode to [Thermal

Cruise Mode].

Target Temperature [50]
Input value range: [0~127]

Tolerance of Temperature [0]
Input value range: [0~7]

Fan Out Start-Up Value [127]
Input value range: [0~255]

Fan Out Stop Value [100]
The Fan Out value decreases to this value if the temperature reaches below

the lowest temperature limit. Input value range: [0~255]

Fan Out Stop Time [60]
Determines the amount of time it takes for the the Fan Out value to fall from

the stop value to zero. Input value range: [0~255]

Critical Temperature [75]
Determines the amount of time Fan Out takes to decrease its value by one

step. Input value range: [0~255]

Fan Out Step Up Time [10]
Determines the amount of time Fan Out takes to increase its value by one

step. Input value range: [0~255]

Fan Out Step Down Time [10]
Determines the amount of time Fan Out takes to decrease its value by one

step in intervals of 0.1 seconds. Input value range: [0~255]

Advertising