E M B - A 5 0 M

Appendix A Programming the Watchdog Timer A-5

1: WDT value is equal to 0.
0: WDT value is not equal to 0.


Watch Dog Timer Configuration Register (Index=72h,
Default=001s0000b)

Bit Description

7

WDT Time-out Value Select 1
1: Second
0: Minute

6

WDT Output through KRST (pulse) Enable
1: Enable
0: Disable

5

WDT Time-out Value Extra Select
1: 64ms x WDT Time-out value (default=4s)
0: Determined by WDT Time-out value select 1 (bit 7 of this
register)

4

WDT Output through PWRGD Enable
1: Enable
0: Disable
During LRESET# this bit is selected by JP2 power-on
strapping option.

3-0

Interrupt Level Select for WDT
Please refer to Table 8-9 Interrupt Level Mapping Table


Watch Dog Timer Time-out Value (LSB) Register (Index=73h,
Default=38h)

Bit Description

7-0 WDT

Time-out

Value

7-0


Watch Dog Timer Time-out Value (MSB) Register (Index=74h,
Default=00h)

Bit Description

7-0 WDT

Time-out

Value