2.7 LCD INVERTER Voltage Selection (JP1)

JP1

Function

1-2 +5V

(Default)

2-3 +12V

2.8 COM2 Ring/+5V/+12V Selection (JP2)

JP2

Function

1-2 +12V

3-4 +5V

5-6 Ring

(Default)

2.9 LCD Voltage Selection (JP3)

JP3

Function

1-2 +5V

2-3 +3.3V

(Default)

2.10 Auto Power Button (JP4)

JP4

Function

1-2

Auto power button

2-3

Not use auto power button (Default)

2.11 Clear CMOS (JP5)

JP5

Function

1-2 Protected

(Default)

2-3 Clear