AAEON AEC-6967 User Manual

Page 87

Advertising
background image

E m b e d d e d C o n t r o l l e r

A E C - 6 9 6 7

Appendix A Programming the Watchdog Timer

A-2

A.1 Watchdog Timer Initial Program

Table 1 : SuperIO relative register table

Default

Value

Note

Index 0x2E(Note1)

SIO MB PnP Mode Index Register
0x2E or 0x4E

Data 0x2F(Note2)

SIO MB PnP Mode Data Register
0x2F or 0x4F

Table 2 : Watchdog relative register table

LDN Register

BitNum

Value

Note

Timer

Counter

0x07

(Note3)

0xF6

(Note4)

(Note24)

Time of watchdog
timer (0~255)
This register is byte
access

Counting

Unit

0x07

(Note5)

0xF5

(Note6)

3

(Note7)

0(Note8)

Select time unit.
0: second
1: minute

Watchdog

Enable

0x07

(Note9)

0xF5

(Note10)

5

(Note11)

1

(Note12)

0: Disable
1: Enable

Timeout

Status

0x07

(Note13)

0xF5

(Note14)

6

(Note15)

1

1:Clear timeout status

Output

Mode

0x07

(Note16)

0xF5

(Note17)

4

(Note18)

1

(Note19)

Select WDTRST#
output mode
0: level
1: pulse

WDTRST

output

0x07

(Note20)

0xFA

(Note21)

0

(Note22)

1(Note2

3)

Enable/Disable
time out output via
WDTRST#
0: Disable
1: Enable

Advertising