ABUS AZ4299 Terxon SX Base Kit with sounder Installation User Manual

Page 136

Advertising
background image

60

UK

182 Last output for settling time

This time sets a delay in the alarm report for detectors in
the exit area. The sirens are switched off during this time
and the alarm centre ignores the alarms.
To change the settings:

1. On the control unit, enter:

182

2. The LCD display shows: 182:Settling 07

3. Via the keypad, select from the following items

and press:

07-12

Settling 07-12


4. Confirm your input. On the control unit, enter:

.

5. The control unit acknowledges your input with a

double “beep” tone and shows Installer Mode.

183 Change display

To change the settings:

1. On the control unit, enter:

183

2. The LCD display shows: 183: Terxon SX

3. Use the keyboard to change the display. Use the

keyboard in the same way as when assigning the
zone names.


4. Confirm your input. On the control unit, enter:

.

5. The control unit acknowledges your input with a

double “beep” tone and shows Installer Mode.

184 Fire signal transmitter

To change the settings:

1. On the control unit, enter:

184

2. The LCD display shows: 184:FirePulseOFF

3. Via the keypad, select from the following items

and press:

0

FirePulseOFF
Normal 2-tone fire alarm

1

FirePulseON

Transmits a pulse signal to the outputs
connected as „Siren“ (81-83=00)


4. Confirm your input. On the control unit, enter:

.

5. The control unit acknowledges your input with a

double “beep” tone and shows Installer Mode.

185 Key switch auto reset

To change the settings:

1. On the control unit, enter:

185

2. The LCD display shows: 185:KsAutoRstOFF

3. Via the keypad, select from the following items

and press:

0

KsAutoRstOFF
The user must manually reset any
triggered zones.

1

KsAutoRstON
The system automatically resets zone
types KM or KF when the user activates
using the key switch.


4. Confirm your input. On the control unit, enter:

.

5. The control unit acknowledges your input with a

double “beep” tone and shows Installer Mode.

201 Prog. entry delay time 1

Define entry delay time 25.40 mm seconds. Proceed as
follows:

1. On the control unit, enter:

201

2. The LCD display shows: 201: Entry 1=20

3. Via the keypad, enter the entry delay time.

4. Confirm your input by pressing.

.

5. The control unit acknowledges your input with a

double “beep” tone and shows Installer Mode.