M, ma stg wall mount, Technical installation data – Alera Lighting M, MA Staggered Wall Mount User Manual

Page 2

Advertising
background image

© 2013 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications
without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com

Page 2/2 Rev. 09/23/13

Beams / M, MA STG WM TID

M, MA STG WAll MounT

Technical Installation Data

1. Attach connector brackets to reflector on each

housing using the #8 screws. Ensure the angles are
in the same direction on each housing. (4 total)

2. Insert Top Light Seal halfway into one of the

Housings.

3. Insert Aligner with Pem Studs into the "C" channel

slots on one of the housings (2 total)

4. Use the #8 nuts to secure the aligner to the housing

A. (2 total)

5. Attach each Light Seal to the Aligner using the #8

nuts. Do not tighten the nut at this point. (2 total)

6. Butt Housing B against Housing A while engaging

Top Light Seal and electrically connecting in-row
wiring.

7. Engage the connector brackets with the screws

provided. Tighten the screws until the housings are
pulled together.

8. Secure the Aligner in Housing B with #8 nuts

provided and tighten.

9. Tighten the nuts on the side light shields.

connection inStructionS

Housing A

Housing B

Aligner w/ Pem

Studs (2 places)

#8 Nuts

(6 Places)

Light Seal (2 Places)

#8 Screws (6 places)

Conn Brackets (4 Places)

inStallation inStructionS

1. Mount wall brackets orienting the bracket ears upward. At feed location pass supply leads through large hole in bracket.
2. Remove fixture shielding (lens, baffle, louver, etc.)
3. Remove end caps assemblies by disengaging wire form from slot in electrical tray.
4. Remove electrical tray from fixture.
5. Mount fixture housing to wall brackets by rotating the bottom of the housing slightly outward passing the wall bracket ears (and supply

leads) through the slot near the top of the housing. Rotate the housing into a vertical position so the back of the housing is flush with the
wall bracket and install bracket mounting screw from the inside bottom of the housing.

6. Connect supply leads to electrical tray components; black to black, white to white and green to ground according to code requirements.
7. Remount electrical tray.
8. Reinstall end cap assemblies.
9. Reinstall shielding.

Wall

Electrical supply into fixture

(2) Mounting Brackets

Plaster ring mounted in wall by others