012-306-C0-004, Rev. D 02/2006

1 of 2

Patented technology extends battery life and improves capacity

Each battery receives the precise voltage required to maintain optimum charge

Replace single batteries as they fail, not the entire string

Spreads charge voltage equally across batteries – batteries no longer need to be matched

Maintains battery voltage as they age

Passes individual battery voltages to status monitoring equipment

Charge Management Technology (CMT)
The AlphaGuard installs directly on top of one of the batteries in the string. A wire harness connects the AlphaGuard to each of the batteries in the string.
Both 36V (3 battery) and 48V (4 battery) versions are available. One AlphaGuard is required per battery string. The AlphaGuard performs electrical
compensation for differences in individual batteries in the string. The unit can be confi gured to pass measurements from the battery string to a status
monitoring device (EDSM card, DOCSIS transponder, etc.) via an interface cable.

Model

Description

AG-CMT-3SC AlphaGuard manages 3 batteries*
AG-CMT-4SC AlphaGuard manages 4 batteries*
* Includes 6' battery cables

AlphaGuard™ AG/CMT Installation Instructions

Features:

Alpha Technologies

Patented

IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS: This document contains important instructions for the AlphaGuard that should be followed during the installation.

• Before making connection to batteries, refer to the battery manufacturer’s installation manual and maintenance instructions.
• Before making connection to a power supply, refer to the power supply manufacturer’s installation instructions.

The AlphaGuard requires ventilation for proper operation and optimum life. Do not place in a location that blocks the vents, or in a position