Alpha Technologies XP-EDH-A2 User Manual

Power, Alpha xm series 2 power supply, Caution

Advertising
background image

1

745-838-C5-001 Rev. A

Power

Alpha XP-EDH-A2 Transponder Field Installation Instructions

A grounded Surge Protector (Alpha P/N 162-028-10) or equivalent) is required for all installations.

Do not place the transponder on top of the power supply or the batteries.

Make all battery harness connections to the batteries and connect the interface cables to the power supply before connecting the cables to the

transponder.

First, verify the transponder bears the warning label as shown at right. This indicates the unit is an XP-EDH-A2,

and the jump and switch settings described in this instruction will work properly.

Verify the transponder's MAC address is loaded into the CMTS, and DOCSIS configuration file options should be

set. Detailed instructions for field installation procedures are available in the XP-EDH-A2 Technical Manual

(Alpha P/N 745-838-B2) available at www.alpha.com.

Alpha XM Series 2 Power Supply

1. Switch the battery breaker OFF.

2. Remove the Inverter Module from the power supply. See the power supply's technical manual for instructions.

3. Position jumpers and switches as shown below.

ON

USM2.5

48V and ≥ 20A

ON

48V and <20A

ON

<48V and ≥ 20A

ON

ON

<48V and <20A

ON

JUMPED

ON

ON

1

2

3

ON

USM2

ON

48V and ≥ 20A

ON

48V and <20A

<48V and ≥ 20A

ON

<48V and <20A

ON

JP2: 2-3 Jumped

JP1 (5V Position)

SW1

SW1 Settings:

SW1 Settings:

SW2 Setting:

SW1

SW2

UNLATCH RIBBON CABLE RETAINER

BEFORE FULLY REMOVING MODULE.

OUTPUT 1

OUTPUT 2

N + 1

SSR

OUTPUT

N

L

LRI

W

H

T

RE

D

B

LA

C

K

BATTERY

B

LK

INPUT

BREAKER

BATTERY

transformer

m o d u l e

module

inverter

ALARM

OUTPUT

ESC

M

TEMP

PROBE

BLACK

RED

TEST

S
S

C

O

Y

TMPR

Power Supply

PWR

Power

14 PIN

US
DS

Battery

18 PIN

16 PIN

ONLINE

DOCSIS Transponder

AlphaNet

0A C4 36

System RF Cable in

To Battery Harness

Black

wire

Yellow

wire

To Batteries

Important!

Plug in the 13 pin

connector so that the

black wire is in pin 1 (the

bottommost pin) and two

open pins are left at the

top for tamper switch

connector.

AC voltage input (USM2 cards only)*

Power Supply Interface Cable

cbl

-

ps

-

intfc

-

01-003, Alpha p/n: 875-565-10

* CBL-PS-PWR-01-001 120V p/n: 875-563-10
CBL-PS-PWR-03-002 220V p/n: 875-562-10 (3' cord with IEC C13 connector and 220V US NEMA 6-15 plug)

CAUTION!

(AC Scaling of

Output Voltage)

Advertising