4.3

Smart Display Modes, continued

4.3.5 Menu Structure/Navigation

(from Active Alarms screen)

Auto-Scroll Information

To Operation Normal

(Auto-scroll Information)

OPERATION NORMAL

OPERATION NORMAL

(Single-step Information)

Back to

Auto-Scroll

SETUP MENU

(Auto-scroll Information)

Back to

Auto-scroll

To

Single-step

Sample Active

Alarm

To Single-step

Help Screens

Back to Auto-Scroll

To Single-step

To Active Alarms

220GOLD

220HPL-FT

220GXL

210GXL

195GXL

195GOLD

180GXL

165GXL

115HPL-FT

85GXL

70HPL-FT

***ACTIVE ALARMS***

(Auto-scroll Information)

SELF TEST FAIL

LOW BATT VOLTS

HIGH BATT VOLTS

NO BATTERIES

BATT TEMP PROBE

LINE ISOLATION

OUTPUT FAILURE

OUTPUT OVERLOAD

OUTPUT 1 TRIPPED

OUTPUT 2 TRIPPED

CHARGER FAILURE

INPUT FAILURE

INV DISCONNECTED

INVERTER TEMP

TAP FUSE FAIL

CONFIG ERROR

N+1 IN USE

N+1 FAULT

***ACTIVE ALARMS***

(Single-step Information)

Output Overload

Single-step Information

1. OUTPUT SHORT CKT?

2. TOO MUCH LOAD

3. CHK OUTPUT CURRENT

COMMS INFO

Float V/C = 2.27 V

SETUP MENU

CODE VER = 7.01.0

DEVICE ADDRESS= 1

ALPHACELL = OTHER

FLOAT V/C=2.27

ACCEPT V/C=2.40

TEMP COMP=5mV

BATT CAPACITY=100Ah

STANDBY TIME=65M

STANDBY EVENTS=12

TOTAL RUN TIME = 365D

SELF TEST = OFF

TEST INHIBIT

TEST INTERVAL

TEST DURATION = 10M

TEST COUNTDOWN

FREQ RANGE = 3.0Hz

PIM OPTION = YES

RESET OUT 1

RESET OUT 2

OVERCURRENT 1 = 15.0A

OVERCURRENT 2 = 15.0A

RETRY DELAY = 60s

RETRY LIMIT = 20

OVER CURR TOL = 3000

N+1 VALID = NO

SET DEFAULTS = NO

SELECT LANGUAGE

COMMS INFO

(Single-step Information)

To Single-step

(Single-step Information)

CODE VER = 7.01.0

DEVICE ADDRESS= 1

ALPHACELL = OTHER

FLOAT V/C=2.27

ACCEPT V/C=2.40

TEMP COMP=5mV

BATT CAPACITY=100Ah

STANDBY TIME=65M

STANDBY EVENTS=12

TOTAL RUN TIME = 365D

SELF TEST = OFF

TEST INTERVAL

TEST INHIBIT

TEST DURATION = 10M

TEST COUNTDOWN

FREQ. RANGE = 3.0Hz

TAP SWITCH

PIM OPTION = YES

RESET OUT 1

RESET OUT 2

OVERCURRENT 1 = 15.0A

OVERCURRENT 2 = 15.0A

RETRY DELAY = 60s

RETRY LIMIT = 20

OVER CURR TOL = 3000

N+1 VALID = NO

SET DEFAULTS = NO

SELECT LANGUAGE

(Auto-scroll Information)

Back Auto-scroll

To Program Mode

To Accept New Data

To Accept

New Data

To Abort

Edit using

Back to Single-st

ep Setup Menu

LANGUAGE =

ENGLISH

SPANISH

FRENCH

PORTUGUESE

GERMAN

Output Overload

(Auto-scroll Information)

1. OUTPUT SHORT CKT?

2. TOO MUCH LOAD

3. CHK OUTPUT CURRENT

Sample Active

Alarm

Back to Auto-scroll

Help Screens

To Help screens

for selected alarm

SELF TEST FAIL

LOW BATT VOLTS

HIGH BATT VOLTS

NO BATTERIES

BATT TEMP PROBE

LINE ISOLATION

OUTPUT FAILURE

OUTPUT OVERLOAD

OUTPUT 1 TRIPPED

OUTPUT 2 TRIPPED

CHARGER FAILURE

INPUT FAILURE

INV DISCONNECTED

INVERTER TEMP

TAP FUSE FAIL

CONFIG ERROR

N+1 IN USE

N+1 FAULT

Back to

Auto-scroll

To

Single-step

To Setup Menu

Back to

COMMS Info

To

COMMS Info

Back to

Operation Normal

Back to Single-st

ep Setup Menu

OPER MODE = LINE

INPUT VOLTAGE 120V

INPUT FREQUENCY 60Hz

OUTPUT VOLTAGE 89V

OUTPUT 1 CURRENT 12.2A

OUTPUT 2 CURRENT 12.0A

OUTPUT WATTS (W)

OUTPUT VA 1060

PERCENT LOAD 80%

CHARGER MODE = FLOAT

BATT VOLTAGE 40.5V

BATTERY TEMP 37°C

CHARGER CURRENT 8.2A

12 EVENTS 65 MIN

CM = 00:90:EA:00:30:54

CM192.168.1.151

CMRx PWR -6.8dBMv

CMTx PWR 41.0dBMv

DN FREQ = 300.000 MHz

UP FREQ = 15.000 MHz

SW 4.5.9.0_00.77CO-N

BATT A1=13.1 A2=14.0

BATT A3=13.5 B1=13.1

BATT B2=14.0 A2=13.5

CM = 00:90:EA:00:30:54

CM192.168.1.151

CMRx PWR -6.8dBMv

CMTx PWR 41.0dBMv

DN FREQ = 300.000 MHz

UP FREQ = 15.000 MHz

SW 4.5.9.0_00.77CO-N

BATT A1=13.1 A2=14.0

BATT A3=13.5 B1=13.1

BATT B2=14.0 A2=13.5

When an AlphaCell battery is

selected, the values for Float,

Accept, Temp Comp and

Battery Capacity are

automatically selected and not

shown in the Smart Diaplay.

Once the battery data has

been updated, the operator

will be prompted to select the

number of battery strings used

in the system.

OPER MODE = LINE

INPUT VOLTAGE 120V

OUTPUT VOLTAGE 89V

OUTPUT 1 CURRENT 12.2A

OUTPUT 2 CURRENT 12.0A

CHARGER MODE = FLOAT

BATT VOLTAGE 40.5V

BATTERY TEMP 37°C

CHARGER CURRENT 8.2A

12 EVENTS 65 MIN

*

*

*

Visible when AlphaCell = Other

**

Visible only on Auto-scroll screen

***

Visible when PIM option = Yes

***

***

*

*

Visible only on Single-step screen

LEGEND

Description

Control panel

Key

Smart Display

Symbol

UP

DOWN

ENTER

ESCAPE

<ESC>

*

**

*