Alpha Technologies AlphaCell SMU User Manual

Page 8

Advertising
background image

745-680-B9-001

8

1.0 Introduction

3.0 Specifi cations

2.0 Theory of Operation

Valve Regulated Lead Acid (VRLA) batteries make use of a process called recombination. By
reforming the water lost during electrolysis, recombination eliminates the need for regular battery
checks and for refi lling the battery water. The chemical reactions are as follows:

Pb + PbO

2

+ 2H

2

SO

4

2PbSO

4

+ 2H

2

O

2Pb + O

2

2PbO

PbO + H

2

SO

4

PbSO

4

+ H

2

O

Discharge

Charge

The AlphaCell SMU battery with sealed gas recombination technology is specifi cally designed
for telecommunication applications, and is available with capacities from 200Ah to 2,000Ah. The
AlphaCell SMU Series of batteries require less space than conventional VRLA batteries and are
structurally arranged to eliminate dislodging and slippage caused by vibrations over time.
Features and Benefi ts:

10+ year life

• Recombination

effi ciency approaching 99.9%

Low self discharge maximizes shelf life

Strong, corrosion resistant grid design

Modular unit structure allows for minimal footprint

• Unique,

fl exible connectors that make for convenient installation and effi cient connections

Shockproof external design

Fig. 3-1, Battery Construction

Terminal (+)

Safety Valve

Terminal (-)

Negative Strap

Positive Plate

Separator

Negative Plate

Container

Positive Strap

Cover