Safety precautions

Fire and explosion

1. Spark and open flames are strictly prohibited.

Paints can be highly flammable and can cause fire.

Avoid any ignition sources such as smoking, open flames, electrical goods, etc.

2. Never use the following HALGOGENATED HYDROCARBON SOLVENTS

which can cause cracks or dissolution on gun body (aluminum) by chemical reaction.

unsuitable solvents:methyl chloride, dichloromethane, 1.2-dichloroethane,carbon tetrachloride,

trichloroethylene, 1.1.1-trichloroethane

Be sure that all fluids and solvents are compatible with gun parts.

We are ready to supply a material list used in the product)

3. Securely ground spray gun by using air hose with built-in ground wire.

Ground wire : Less than 1MΩ. Check the earth stability periodically.

If not, insufficient grounding can cause fire and explosion due to static electric sparking.

Improper use of equipment

1. Never point gun toward people or animal.

If done, it can cause inflammation of eyes and skin or bodily injury.

2. Never exceed maximum operating pressure and

maximum operating Temperature.

3. Be sure to release air and fluid pressures before cleaning, disassembling or servicing.

If not, remaining pressure can cause bodily injury due to improper operation or scattering cleaning liquid.

In order to release pressure, first stop supply of compressed air, fluid and thinner to spray gun.

Then remove fluid adj. knob and pull fluid needle set toward you.

4. Tip of fluid needle set has a sharp point. .

Do not touch the tip of fluid needle during maintenance for the protection of the human body.

Protection of human body

1Use in a well-ventilated site by using spray booth.

If not, poor ventilation can cause organic solvent poisoning and catch fire.

2Always wear protective gear safety glasses, mask, gloves.

If not, cleaning liquid, etc., can cause inflammation of eyes and skin.

If you feel something wrong with eyes or skin, immediately see a doctor.

3Wear earplugs if necessary.

Noise level can exceed 85dB(A), depending on operating conditions and painting site

4If operators pull the trigger many times during operation, it may cause carpal tunnel syndrome.

Be sure to take a rest if you feel tired.

Other precautions

1Never alter this spray gun.

If done, it can cause insufficient performance and failure.

2Enter working areas of other equipment (robots, reciprocators, etc.) after machines are turned off.

If not, contact with them can cause injury.

3Never spray foods or chemicals through this gun.

If done, it can cause accident by corrosion of fluid passages or adversely affect health by mixed foreign matter.

4If something goes wrong, immediately stop operation and find the cause. Do not use again until you have solved the problem.

How to connect

-

Use clean air filtered through air dryer and air filter. ・・・If not, dirty air can cause painting failure.

-

When you use this gun for the first time after purchasing, adjust fluid needle packing set.

Slowly tighten fluid packing seat and loosen a bit when fluid needle set does not return smoothly, and adjust so that fluid needle set smoothly

moves.

-

If you use this gun for the first time after purchasing, clean fluid passages spraying thinner and remove rust preventive oil.

If not, remaining preventive oil can cause painting failure such as fish eyes.

-

Firmly fix hose or container to spray gun.・・・If not, disconnection of hose and drop of container can cause bodily injury.

Job1. Connect an air hose to air nipple tightly.
Job2. Connect an applicable cup to fluid nipple tightly.
Job3. Flush the gun fluid passage with a compatible solvent.
Job4. Pour paint into container, test spray and adjust fluid output as well as pattern width