MM-ESS6008MS Intellamatic Smart Charger Quick Start Guide

• Plug Charger into 120V outlet. Red LED on panel will indicate Charger is

ready when Power Switch is in either the Charge or Crank Position.
Warning: use Crank setting only for Crank assisting a battery.

• Select battery type to be charged, Either Flooded or AGM/ Gel-Cell-Sealed

battery. If not sure of battery type use AGM /Gel/Sealed mode to prevent
damage to battery in the event it is a AGM/Gel or Sealed battery.

• Connect Red clamp to positive battery post and black to negative battery

post, Green LED will illuminate for approximately 4 seconds to indicate
proper polarity. If Green LED does not come on check for proper clamp
connection. This charger is polarity indicated and protected so no damage
will occur by accidental reverse hook-up. If Red LED starts Flashing then
Battery is connected backwards.

• If you’re sure the polarity is correct and the Green LED light does not come

on hold the Dead Battery Override button down for 5 seconds this will put a
small surface charge on the battery to start the charging process.

• Yellow LED will stay on steady when charging. This charger has an

automatic Deep Discharge mode which will try and recover deeply
discharged or sulfated batteries in this mode the Yellow and Green LED’s
will alternate. When the yellow LED starts to blink the battery is at or above
80% state of charge. The Green LED will start to blink when battery is
completely charged.

• During the first 15 minutes this charger will automatically test the battery

for its ability to hold a charge. If during any of these tests the charger
determines the battery is not holding a charge the Red LED will blink
indicating a weak or defective battery.

• This charger also has power supply mode. On the battery type selector

switch select the center position- ESS. This will put the charger in a mode of
operation that will put out a clean 13.7 Volts at up to 70 Amps for extended
service procedures such as vehicle re-flash or drivability diagnostics.