GROUNDING AND AC POWER CORD CONNECTION INSTRUCTIONS

The charger should be grounded to reduce the risk of electric shock. This charger is equipped with an electric cord having an equipment
grounding conductor and a grounding plug. The plug must be plugged into an outlet that is properly installed and grounded in accordance with
all local codes and ordinances.

DANGER.

Never alter the AC cord or plug provided - if it will not fit

the outlet, have a proper outlet installed by a qualified electrician.
Improper connection can result in a risk of an electric shock. This
battery charger is for use on a nominal 120-volt circuit, and has a
grounding plug that looks like the plug illustrated in FIGURE (A). A
temporary adapter, which looks like the adapter illustrated in FIGURE
(C), may be used to connect this plug to a two-pole receptacle, as
shown in FIGURE (B), until a properly grounded outlet can be
installed by a qualified electrician.

GROUNDED

OUTLET

GROUNDING METHODS

GROUNDING

MEANS

ADAPTER

COVER OF GROUNDED

OUTLET BOX

(A)

(B)

(C

ADAPTER

)

DANGER.

Before using an adapter as illustrated, be certain that the center screw of the outlet plate is grounded. The green-colored rigid

ear or lug extending from the adapter must be connected to a properly grounded outlet - make certain it is grounded. If necessary, replace the
original outlet cover plate screw with a longer screw that will secure the adapter ear or lug to the outlet cover plate and make ground
connection to grounded outlet.
NOTE: USE OF AN ADAPTER IS NOT ALLOWED IN CANADA. IF A GROUNDING TYPE RECEPTACLE IS NOT AVAILABLE, DO NOT
USE THIS APPLIANCE UNTIL THE PROPER OUTLET IS INSTALLED BY A QUALIFIED ELECTRICIAN.


21.

LENGTH OF CHARGE

a.

Test the battery for state of charge. Do not charge if it is over 75% charged or the battery is determined to be defective.

b.

Set beginning amps charge rate for size of battery and state of charge per charts

c.

Charge for length of time per charge,

d.

Discontinue charge when the specific gravity of electrolyte reaches 1.260 or above. A temperature compensating hydrometer should be

used for this reading. Discontinue charge if the battery begins to gas excessively or when the temperature of the electrolyte reaches
approximately 120

°F. Do not overcharge batteries. Overcharging results in excessive water loss and eventual damage to the battery.

23.6

11.8

5.9

1.110

23.8

11.9

5.95

1.140

24.2

12.1

6.05

1.185

24.8

12.4

6.2

1.225

25%

50%

75%

DEAD

Open Circuit Voltage 24V

Open Circuit Voltage 12V

Open Circuit Voltage 6V

Specific Gravity

STATE OF CHARGE

STATE OF CHARGE TABLE

Cold Cranking Amps

Reserve Capacity

Ampere Hours

BATTERY SIZE

60

90

350

80+

100+

400+

40

60

275

BATTERY SIZE TABLE

LARGE

MEDIUM

SMALL

BATTERY SIZE %CHARGE

0-25

30

30

30

45

45

50

20

20

20

30

35

40

5

5

20

25

15

25

20

35

55

15

25

45

10

20

30

20

40

55

15

30

50

10

20

30

30

60

90

25

45

70

15

30

45

15

15 15 15

10

10

10 10 10

15 30 45 60 75 90

MINUTES

A

M

P
E
R
E
S

SMALL

MEDIUM

LARGE

CHARGE RATE Vs. MINUTES CHARGE

25-50

50-75

50-75

25-50

0-25

50-75

25-50

0-25

ASSEMBLY INSTRUCTIONS