ATAS ScanRoof User Manual

Installation guide, Top view, Open framing solid substrate

Advertising
background image

SCANROOF panels are always installed from lower right
of any roof section to upper left. Each fully applied
panel affords 18.1 square feet of coverage and each
square (100 square feet - 5.52 panels) of SCANROOF
weighs approximately 145 pounds.

Minimum roof slope - 3:12.

21 Modules - 13’-10” (nom.) overall length

Lap Area

Lap Area

20 Modules - 13’-2” (nom.) Coverage

7-7/8”

21”

16-1/2” r

ef

.

Top View

FASTENER REQUIREMENTS

SWR8XX - “Stitch Screws” 10 per panel
SWR9XX - 10 for each panel installed at eave
RSS014 or SWR970 - Anchor Screws 8 per panel

(Use RSS014 for attachment to metal and SWR970 for attachment to wood.)
For basic wind speeds of 100 mph - Panels can obtain 140 mph winds
Consult ATAS for more information.

Appropriate
Anchor Screw

Scan Roof Panel

SWR8XX Stitch Screws

Intergral “Z” Purlin

Scan Roof Panel

Substrate
Line

HORIZONTAL LAP

1-1/2” Hat
Channel

2” X 4”
Wood Stud

Open Framing

Solid Substrate

4’ Max

Appropriate
Anchor Screw

SWR8XX Stitch Screws

Intergral “Z” Purlin

Panel Overlap

21” Nom.

16-1/2” (nom.) coverage

2” Nom.

1”

Side View

Installation Guide

Review and understand complete
guide before beginning installation.
This guide has been prepared as
suggested details for particular design
conditions. Each condition has certain
limitations to performance, aesthetics or
economics. Professionals qualified to assess
this information for a specific projects should
determine that the selection and installation are made
to their requirements. ATAS cannot assume any
responsibility for the actual selection and/or installation
of materials. The panels, flashing and trim shown in this
guide are illustrated over solid and square substrate. It
is assumed that the structure has been designed and
prepared in accordance with local building codes,
including appropriate underlayment.