Panel

#1

Panel

#2

Panel

#3

Panel

#4

Panel

#8

Panel

#7

Panel

#14

Cut to

Fit

Panel

#15

Panel

#9

Panel

#5

Panel

#6

Panel

#10

Panel

#16

Panel

#17

Panel

#11

Panel

#18

Panel

#12

Panel

#19

Panel

#20

Panel #13

Cut to Fit

These edges
to fit into gable

utility cleat

First row
may vary to
obtain roof
symmetry

Clips

16” Nom.

5’-0”

Nom.

3’-0”
Nom.

Slope

See Gable
Detail on
Page 2

5'

3"

16"

NO

M.

3'

12" T

YP.

16"

NO

M.

3"

12" TYP.

Standing Seam Shingle Panels are available in

two sizes: 16" (nom.) wide by either 3' long (nom.

coverage) or 5' long (nom. coverage). Minimum

roof pitch is 4:12.

Panel Installation Details

Standing Seam Shingle is installed in a staggered

pattern, from eave to ridge, left to right. Start in

the bottom left corner of the roof plane with a 5'

panel. The pattern must stagger along eave line

with 5' and 3' panels. For panel sequence follow

numbered pattern to the left.

Panels are fastened to a solid substrate with side

clips spaced as shown and using a #10 screw.

Fasten at top of panel using two #10 screws per

panel through the factory mounted cleat.

Published panel width dimensions are to be considered

as nominal dimensions. Variations in overall coverage

may occur at installation due to typical manipulating of

panels during attachment to the roof assembly.

Installation Guide

Review and understand

complete guide before

beginning installation.

This guide has been prepared

as suggested details to

particular design conditions.

Each condition has certain

limitations to performance, aethetics

or economics. Professionals qualified to assess the

information regarding suitability for a specific project

should determine that the selection and installation

are made to their requirements. ATAS cannot assume

any responsibility for the actual selection and/or

installation of materials. The panels, flashings and trim

shown in this guide, illustrated over solid and plumb

substrate, assume that the structure has been

designed and prepared in accordance with local

building codes.

Side Seam Detail

Locate 3 clips along the nom. 37 7/8” long side and

5 clips along the 60 7/8” side - see above.

Clip Layout

Factory-Applied Sealant

Between Cleat and Panel at

Fastener Location(s).

Panel

#10 x 1” Screw

Advertising