Installation Guide

Review and understand complete
guide before beginning installation.
This guide has been prepared as sug-
gested details to particular design condi-
tions. Each condition has certain limitations to perform-
ance, aethetics or economics. Professionals qualified to
assess this information for a specific project, should deter-
mine that the selection and installation are made to their
requirements. ATAS cannot assume any responsibility
for the actual selection and/or installation of materials.
The panels, flashings and trim shown in this guide, illus-
trated over solid and plumb substrate, assume that the
structure has been designed and prepared in accordance
with local building codes.

Permashake panels are simulated wood shakes
manufactured from 29 gauge G90 galvanized steel.
They are available in 6 standard colors with a Hylar 500

R

and/or Kynar 5000

R

finish. They measure 10 5/8” (nom.) x

61” (nom.) Minimum recommended roof pitch is 4:12.

Insertion tab at
left end of panel

1” nom. front face with
9/16” nom. tab bent under

1/2” hem on
top surface

Interlock slot on
right end of panel

PANEL INSTALLATION - In environments where ice and water may dam, apply ATA Shield

**

underlayment over entire substrate. Begin installation

over solid deck by applying ATA Shield

*

around perimeters of roof with a minimum of 36” coverage. Then apply ATA Guard

*

or appropriate underlay-

ment over roof deck. Snap a vertical and horizontal line to square up the plane with the eave line. Start at the bottom left hand corner of the roof
plane with a full length panel. Install shingles in a left to right manner from eave to ridge. See below for stagger methods of installation. Fasten
panels to solid substrate with galvanized steel clips using a minimum of three (3) to a panel. Manufacturer recommends the use of 1” wafer head
screws.

Channel trim

STEP STAGGER METHOD
Each course 10” to the left of
the lower course.

Channel trim

RANDOM STAGGER METHOD
Cut and start each course as
follows beginning at the lower left
edge of the roof.

**In areas of high winds and / or heavy
snow loads, a clip is recommended
every 12” with 5 clips per panel.

Section through interlocking slot at right end of panel

60” coverage

Interlock slot at right end

10-5/8”

There are twelve (12) Permashake panels packaged per
carton. Approximately twenty-four (24) panels equal a
square. Panels are always installed left to right and
should have a minimum of three (3) anchor clips.