Notch Panel 2”

Eave Side

Gable Side

Installation Sequence

12”

Typical

Setback

Panel Installation Detail

Snap a vertical line to square up the roof

plane with the eave line. Start in the

bottom left hand corner of the roof

plane with a full length panel. Install

shingles in a left to right manner

starting from the eave. Panel sidelaps

should be staggered with a 12-inch

typical setback. Repeat with a full length

panel every fourth row. Panels are pre-

punched to accommodate five fasteners

per panel. There are 170 fasteners per

square. Manufacturer recommends

using 2” ring shank, galvanized roofing

nails; however, a pneumatic fastener

gun with fasteners that have equivalent

pull out values can also be used. Screw

fastening may be utilized for increased

uplift resistance.

Installation Guide

Review and understand

complete guide before

beginning installation.

This guide has been prepared

as suggested details to

particular design conditions.

Each condition has certain

limitations to performance, aesthetics

or economics. Professionals qualified to assess the

information regarding suitability for a specific project

should determine that the selection and installation

are made to their requirements. ATAS cannot assume

any responsibility for the actual selection and/or

installation of materials. The panels, flashings and trim

shown in this guide, illustrated over solid and plumb

substrate, assume that the structure has been

designed and prepared in accordance with local

building codes.

ADVANTA Shingle’s patented four-way interlock design guards against wind

driven rain and prevents wind uplift. Panels measure 1’ x 3’ with a 3 square

foot net coverage area. There are seventeen (17) panels per carton and two

(2) cartons per square (100 square feet). Panels weigh 95 pounds per square.

Minimum recommended pitch is 3:12, subject to building codes.

**Recommended solid substrate is a minimum 5/8-inch exterior grade plywood or equivalent. Advanta Shingles can be applied over existing roofing materials

in accordance with local building codes. Current roof deck should be structurally sound and capable of anchoring fasteners.

Published panel width dimensions are to be considered as nominal dimensions. Overall panel width dimensions may vary during installation due to

adjustments to accommodate as built roof conditions.

®

Left Hand Shingle
(Applied First)

Right Hand Shingle
(Applied Next)

Solid Substrate**

Solid Substrate**

Upper Panel

Lower Panel

ATA-Guard*

2” Ring Shank
Grommeted Nail or
Screw Fastener for
increased uplift
resistance.

Left/Right End Lap Joint

Top/Bottom Lap Joint

Advertising