ATAS Span Wall BWS240 User Manual

Atas international, inc, Specification data sheet, Belvedere panel

Advertising
background image

ATAS INTERNATIONAL, INC.

SPECIFICATION DATA SHEET

1.PRODUCT NAME

BELVEDERE PANEL

SPAN WALL

BWS240

2. MANUFACTURER

ATAS INTERNATIONAL, INC.

Website: www.atas.com

Email: [email protected]

Corporate Headquarters:

Allentown, PA 18106

Phone: (610) 395-8445

Fax: (610) 395-9342

Western Facility:

Mesa, AZ 85204

Phone: (480) 558-7210

Fax: (480) 558-7217

Southern Facility:

Maryville, TN 37801

Phone: (800) 468-1441

3. PRODUCT DESCRIPTION

Basic Uses:

Span Wall is a structural wall panel that offers

design freedom for all types of buildings.

The panel can be installed either on solid

substrate or spaced framing.

Composition & Materials:

Standard Offerings: Span Wall is roll-formed

from .032 (embossed only), .040 and .050

Aluminum; 24 gauge Metallic Coated Steel

(embossed only).

Special Offerings: 20 and 22 gauge Metallic

Coated Steel; 20, 22 and 24 gauge 55% Al-Zn

alloy Coated Steel with acrylic coating may be

specified, subject to minimum quantities and

lead time.

Sizes and Profiles:

Span Wall has a 4” high rib and is 24”

wide. Panel lengths are cut to customer

specifications, with a minimum of 9’-0”

maximum to transportation limitations and/or

product and project design considerations.

Colors & Finishes:

A choice of 30 stock colors is available in a

KYNAR 500® PVDF or HYLAR 5000® PVDF

finish. (Request color chart or chips). An

anodized finish is available in Clear or Dark

Bronze. Texture may be smooth or embossed,

depending on gauge. Panels can be solid or

perforated.

4. TECHNICAL DATA

KYNAR 500® PVDF or HYLAR 5000® PVDF

based finishes tested by paint supplier for:

Dry Film Thickness: ASTM D 1005, ASTM D

1400, ASTM D 4138 or ASTM D 5796

Specular Gloss: ASTM D 523

Pencil Hardness: ASTM D 3363

T-Bend Flexibility: ASTM D 4145

Mandrel Bend Flexibility: ASTM D 522

Impact Resistance: ASTM D 2794

Adhesion: ASTM D 3359

Water Immersion Resistance: ASTM D 870

Abrasion Resistance: ASTM D 968

Acid Resistance: ASTM D 1308

Acid Rain Resistance (Kesternich):

ASTM G 87 or DIN 50018

Salt Spray: ASTM B 117

Cyclic Salt Spray: ASTM D 5894 and

ASTM D 5487

Humidity Resistance: ASTM D 2247

Accelerated Weathering: ASTM D 822 and

ASTM G155, ASTM G 151 or ASTM G 153

Color Retention, Florida Exposure:

ASTM D 2244

Chalking Resistance – ASTM D 4214

Cleveland Condensing Cabinet: ASTM D 4585

Cure Test, MEK Resistance: ASTM D 5402

Alkali Resistance, Sodium Hydroxide: ASTM D

1308, Procedure 7.2

Flame Spread Rating: ASTM E 84

Organic coatings meet requirements of AAMA

2605 when applied to aluminum.

Panel testing/ratings:

UL Fire resistance rating design numbers: See

www.ul.com, File R12113, or contact ATAS for

current listing.

Galvanized Steel: ASTM A 653

55% Al-Zn alloy Coated Steel : ASTM A 792

Aluminum: ASTM B 209

Coil Coating: ASTM A 755

Field Tested and Approved

Load Tables available upon request.

5. INSTALLATION

Installation is with direct fastening methods.

Installation manuals and hands-on training

via seminars are available through ATAS. Visit

www.atas.com for more information.

6. AVAILABILITY & COST

Availability:

Span Wall panels are available through ATAS

product distributors. A complete line of

related components and trim accessories

is available to complete the wall system. In

addition, a complete line of rainware and

perimeter roof edge trims can be supplied

by ATAS to complement the wall system. Flat

sheet and/or coil stock is available in matching

color for fabrication of related components by

the installing contractor.

Cost:

Contact ATAS product distributors for current

pricing.

7. WARRANTY

Products coated with a fluoropolymer, KYNAR

500® PVDF or HYLAR 5000® PVDF finish carry a

limited warranty against chalking and fading.

8. MAINTENANCE

Span Wall panels are virtually maintenance

free. Surface residue may be easily removed by

conventional cleaning methods. For painted

products, minor scratches should be touched

up with a matching paint, available from the

manufacturer.

9. TECHNICAL SERVICES

Complete technical information and literature

are available at www.atas.com. ATAS will assist

with design ideas and shop drawings.

10. FILING SYSTEM

• www.atas.com

• Additional product information is available

from the manufacturer upon request.

Belvedere

TM

is a trademark of ATAS International, Inc.

Span Wall

TM

is a trademark of ATAS International, Inc.

KYNAR 500

®

is a registered trademark of Arkema.

HYLAR 5000

®

is a registered trademark of Solvay Solexis, Inc.

© ATAS International, Inc.

LRD0213 LAT745

24”

4”

12”

Advertising