SPECIFICATION DATA SHEET

1. PRODUCT NAME

ATA-Guard™

Synthetic Roofing

Underlayment

2. SUPPLIER

ATAS INTERNATIONAL, INC.

website: www.atas.com

email: [email protected]

Corporate Headquarters:

Allentown, PA 18106

Phone: (610) 395-8445

Fax: (610) 395-9342

Western Facility:

Mesa, AZ 85201

Phone: (480) 558-7210

Fax: (480) 558-7217

Southern Facility:

Maryville, TN 37801

Phone: (800) 468-1441

3. PRODUCT DESCRIPTION

Basic Uses:

ATA-Guard

TM

is a highly engineered,

mechanically attached, coated woven

synthetic roofing underlayment for sloped

roofs. It can be used under all types of primary

roofing materials and is approved as an

alternative replacement for Type 15 or Type

30 asphalt roofing felt. ATA-Guard is 5 times

lighter and 25 times stronger than 30# asphalt.

Composition and Materials:

ATA-Guard is 100% asphalt free, reinforced

underlayment. Advanced polymers are

combined to produce a film that is unaffected

by water and resistant to UV for up to 6

months.

Size:

ATA-Guard has a nominal thickness of 30 mils

and is available in rolls 48” wide by 250’ long,

a total area of 1000 sq. ft. Each roll weighs 48

pounds.

Color and Finish:

Polymers are combined to produce a gray

color that is much cooler than traditional

asphalt-based underlayments. The walking

surface has a nodular texture that allows for

steep slope walkability even in wet conditions.

4. TECHNICAL DATA

ASTM E 108

Class A Fire

ASTM D 1970

Nail Sealability

ASTM E 96-00

Permeability 0.05 perms

ASTM D 4869

Water Transmission

ASTM D 226

Tear Strength MD 55 lbs, CD 55 lbs

ASTM D 751-95

Tensile Strength MD 178 lbs,

CD 176 lbs

Burst Strength 300 psi

Elongation MD 20%, CD 20%

ASTM D5261

Weight per Square 4.7 lbs

ASTM D 1777

Minimum Thickness 30 mils

Temperature Range -70°F to 212°F.

5. INSTALLATION

Recommended Application:

ATA-Guard must be installed above properly

ventilated spaces (following local building

code) as it is considered a vapor barrier.

Installation manuals or hands-on training

through seminars are available through ATAS.

Visit www.atas.com for more information.

Application Methods:

ATA-Guard is an air, water and vapor barrier.

It must be installed above properly ventilated

spaces (follow ALL building codes applicable

to your geographical region and structure

type) as it is considered a vapor barrier (.05

perms). The use of a rosin paper slip-sheet

is not required underneath metal roofing

systems. Protrusions from the deck area must

be removed and decks shall have no voids,

damaged or unsupported areas. The use of a

straight edge cutting knives is recommended.

ATA-Guard is laid out horizontally (parallel) to

the eave with the printed side up, and with

the 4” horizontal laps and 6” vertical laps.

Follow the codes for low slope as defined as

2:12 to 4:12 and steep slope greater than 4:12

applications. ATA-Guard must be attached

to the structural roof deck material using 3/8”

head electro galvanized (EG) roofing nails; tin

tag caps & nails; screws with washers; plastic

cap staples or plastic cap nails. Anchoring

to be installed at a minimum as per surface

markings, spaced 6” on center in the vertical

and horizontal laps, and at 12” on center

along the center of the roll in the field as

marked. If the application of ATA-Guard

and the final roofing material occur on the

same day, then the option to use every other

printed anchoring placement is acceptable.

All anchoring devices must be flush, 90

degrees to the roof deck, and tight with the

underlayment surface and the structural roof

deck. For extended exposure (months) or high

wind, double the lap widths as a minimum.

Option: Fold the overlay laps forming a “J”

channel configuration before nailing; using a

compatible sealant between the laps, or using

a peel and stick tape is highly recommended.

For batten secured installations, use only

adequate length nails or screws to secure

battens to the structural roof deck material.

It is recommended to use 3/8” head electro

galvanized roofing nails; plastic cap staples;

plastic cap nails or screws with metal or plastic

washers to secure ATA-Guard to prevent

blow off until the batten system is installed.

When using plastic cap and staples, staple leg

should be a minimum ½” or longer. Do not

install battens directly over any plastic caps.

If this occurs, remove plastic cap staples or

nails, patch the hole, then install cap outside

batten field and continue. Where seams and

joints require sealant or adhesive, use a high

quality, low solvent, Asbestos free, plastic

roofing cement meeting ASTM D-4586 Type

1 (Asbestos free), Federal Spec SS-153 Type 1

(Asbestos free) such as Karnak, Henry, DAP, MB,

Geocel or equivalent. Acceptable alternatives

are butyl rubber, urethane, and EDPM based

caulk or tape sealant. Depending on roof

pitch and surface conditions, blocking may be

required to support materials on the roof

6. AVAILABILITY AND COST

Availability:

ATA-Guard is available through ATAS product

distributors.

Cost:

Contact ATAS product distributors for current

pricing.

7. WARRANTY

ATA-Guard is covered by a fifty (50) year

limited warranty.

8. MAINTENANCE

None when installed in accordance with

manufacturer’s recommendations.

9. TECHNICAL SERVICES

Complete technical information and literature

are available from ATAS International, Inc.

ATAS will assist with design ideas and shop

drawings.

10. FILING SYSTEM

www.atas.com

Additional product information is available

from the manufacturer upon request.

ATA-Guard

TM

is a trademark of ATAS International, Inc

KYNAR 500

®

is a registered trademark of Arkema.

HYLAR 5000

®

is a registered trademark of Solvay Solexis, Inc.

© 2011 ATAS International, Inc.

LRD0711 LAT643