3

Cable and Antenna Analyzer

(continued)

Return Loss

Measurement Range Resolution

0 to 60 dB

0.01 dB

VSWR

Measurement Range

1 to 65

Resolution

0.01

Cable Loss

Measurement Range

0 to 30 dB

Resolution

0.01 dB

Distance-to-Fault

Vertical Range Return Loss

0 to 60 dB

Vertical Range VSWR

1 to 65

Fault Resolution (meters)

(1.5 x 10

8

x vp)/ΔF (vp = propagation velocity, ΔF is F2 – F1 in Hz)

Horizontal Range (meters)

0 to (Data Points – 1) x Fault Resolution, to maximum of 1500 meters (4921 feet)

Measurement Accuracy

@ 23 °C ± 3 °C

Corrected Directivity

≥ 38 dB, InstaCal

calibration

≥ 42 dB, OSL calibration (OSLN50-1, OSLNF50-1)

Return Loss Measurement Uncertainty

Internal Power Meter

Amplitude

Maximum, Minimum, Offset, Relative On/Off, Units, Auto Scale

Average

Running Average, Max Hold On/Off, Run/Hold, Average Mode Cont/Single

Limits

Limit On/Off, Limit Upper/Lower

Frequency Range

50 MHz to 4 GHz

Display Range

–100 dBm to +100 dBm

Measurement Range

–33 dBm to +20 dBm

Offset Range

Max ± 100 dB, user settable value

VSWR

1.5:1 typical

Maximum Power

+27 dBm, ± 45 VDC (damage level)

Connector

Type N(m), 50 Ω

Accuracy

± 0.7 dB (0 dBm, 1 GHz CW, @ 23 °C ± 3 °C)

Frequency Response and Linearity

Additional ± 0.8 dB (± 0.5 dB typical)

Temperature Effect

Additional ± 0.02 dB per 1 °C change (typical)

0.1

1

10

35

30

25

20

15

10

5

0

Magnitude Uncertainty

2 GHz

4 GHz

1

10

100

35

30

25

20

15

10

5

0

Phase Uncertainty

2 GHz

4 GHz

Return Loss (dB)

Magnitude (dB)

Phase (degr

ees)

Return Loss (dB)

Advertising