General Specifications

Size: 270(W) x 165(H) x 61(D) mm

Without protector (option 010)

Weight: 2.2 kg (4.8 lbs) including battery

Size: 284(W) x 200(H) x 77(D) mm

Dimensions and mass

With protector (option 010)

Weight: 2.9 kg (6.4 lbs) including battery

Display

6.5 inch TFT-LCD (640×480, with backlight, transparent type)

Interface

USB 1.1, TypeA×1 memory , Type B×1 USB mass storage).

Data Storage

Internal memory: 20 MB (~1000 traces)
External memory (USB): ~30,000 traces with 512 MB

Power supply

12 VDC, Allowable input voltage range: 10.8 – 15 VDC
100 to 240 VAC, Allowable input voltage range: 90 to 264 V, 50/60 Hz

Battery

Type: Lithium ion
Operating Time

*

1

: 8 hours

Recharge Time: <5 hrs (power off)

Power saving
functions

Backlight off: disable/1–99 minutes
Auto shutdown: disable/1–99 minutes

Vertical scale

0.05, 0.125, 0.25, 0.5, 1.25, 2.5, 5, 6.5 dB/div

IOR setting

1.000000 - 1.999999 (0.000001steps)

Units

km, m, kft, ft, mi

Languages

user selectable (English, Simplified Chinese - contact Anritsu for availability of others)

Sampling Points

*2

Normal: 5001, High density: 20001 or 25001

Sampling Resolution

5 cm (min)

Reflectance Accuracy

Single mode: +2 dB, multimode: +4 dB

Distance accuracy

+ 1m + 3 x measurement distance x 10

-5

+ marker resolution (excluding IOR uncertainty)

Distance Range

Single mode: 0.5, 1, 2.5, 5, 10, 25, 50, 100, 200 km (except 780nm: 0.5, 1, 2.5km)
Multimode: 0.5, 1, 2.5, 5, 10, 25, 50, 100 km

Testing Modes

Fault locate: provides end/break location, end to end loss, fiber length
Standard OTDR: user selectable automatic or manual set-up
Construction OTDR: automated, multi-wavelength testing
Light source: stabilized light source (CW, 270Hz, 1kHz, 2kHz output)
Loss test set (optional): power meter and light source
Visual fault locator (optional): visible red light for fiber identification and troubleshooting
IP test (optional): connectivity and throughput for 10/100/1000 MB

Fiber event analysis

Auto or manual operation, displayed in table format
User defined PASS/FAIL thresholds:
- reflective and non-reflective events: 0.01 to 9.99 dB (0.01 dB steps)
- reflectance: 20.0 to 60.0 dB (0.1 dB steps)
- fiber end/break: 1 to 99 dB (1 dB steps)
Number of detected events: up to 99
Macrobend detection

OTDR trace format

Telcordia universal issue 2 (SR-4731)

Other functions

Real time sweep

*3

: 0.15 second

Loss modes: 2 point loss, dB/km, 2 point LSA, splice loss, ORL
Averaging modes: timed (5 – 180 seconds)
Live Fiber detect : verifies presence of communication light in optical fiber( >-40dBm)
Connection check: Automatic check of OTDR to FUT connection quality
Trace overlay and comparison

Environmental
conditions

Operating temperature and humidity: 0 to +40C,<80% non-condensing)
Storage temperature and humidity: -20 to +60C, <80% non-condensing)
Vibration: Conforming to MIL-T-28800E Class 3
Drop: MIL-T-28800E Style C (20.3 cm corner, surface total 14 times shocks, Power OFF)
Dust proof: MIL-T-28800E Class 2

EMC

EN61326:1997/A1:1998/A2 : 2003 (Class A, Annex A)

Laser Safety

IEC Pub 60825-1:2001 Class:1 model 051, 052, 060, 061, 062 Class:1M model 050
21CFR1040.10 (laser notice no. 50)

Notes

1

Typical, backlight off, sweeping halted at 25

o

C, 6 hours typical continuous testing

2

Either high density value is selected depending on distance range

3

Sampling mode normal. Except models 062, 068 – 1 second or less

Advertising