Atec Agilent-346a User Manual

Page 63

Advertising
background image

63

Figure 11.2. E9638A BNC to
probe tip adapter

General-Purpose Probing
Agilent Logic Analyzers with 90-pin Pod Connectors

Available Accessories

Ground Connector

It is essential to ground every tip
that is in use. For best perform-
ance at high speeds, every tip
should be grounded individually
to ground in the system under
test. For convenience in connect-
ing grounds, you can use the
ground connector, Agilent part
number 16515-27601, to combine
up to four probe tip grounds to
connect to one ground point in
the system under test.

Adapting to Coaxial Connectors

The Agilent E9638A probe tip to
BNC adapter can be used to
connect one of the flying lead
probes of the E5382A to a BNC
connector. To probe other coaxial
connectors, use the E9638A
adapter, a BNC termination, and
an adapter to the other type of
coaxial connector. Refer to
Figure 11.3.

Probe Tip

E9638A Probe tip to
BNC Adapter

BNC 50

Feedthrough

Termination Adapter

BNC to SMA, SMB, SMC,
or other Coaxial Adapter

SMA, SMB, SMC, or
other Coaxial Connector

Probe Tip

E9638A Probe tip to
BNC Adapter

BNC 50

Feedthrough

Termination Adapter

BNC Connector

Figure 11.3. Recommended configurations to probe RF coaxial connectors with
the E5382A flying lead probes

NOTE: Examples of convenient connection which

may result in degraded performance

SIG.

SIG.

"GND CONNECTOR"

16515-27601

Advertising