Atec Dewetron-DEWE-2600 User Manual

Dewe-2600, Additional interfaces and sensors

Advertising
background image

99

Software Components Signal Conditioning Front-ends Instruments Dedicated Instruments DEWE2

www.dewetron.com/dewe-2600

All-In-One

DEWE-2600

High performance portable all-in-one instrument
Flexible mixture of isolated and differential analog inputs
Function panels for digital I/O, counters, sensor supply …
Up to 7 PCI slots for A/D and other cards (1394, ARINC, 1553…)
Fully battery powered (optional)

DEWE-2600 series

Input specifications

DEWE-2600

DEWE-2601

DEWE-2602

Slots for DAQ or PAD modules

16

-

16

MDAQ input channels

-

Up to 80 (BNC connectors)

Up to 32

Up to 64 (DSUB connectors)

Available panel space

2 x 2U

1 x 4U and 1x 4.5 U

2 x 2U

Main system

1)

Total PCI-slots

2 full / 2 half length

4 full / 3 half length

2 full / 2 half length

Hard disk

1 TB removable HDD

Data throughput

Typ. 80 MB/s

2)

Power supply

95 to 260 V

AC

Display

15” TFT display, 1280 x 800 pixel

Processor

Intel

®

Core™ i5/i7

RAM

3 GB

Ethernet

2 x 1 Gbit LAN

USB interfaces

4

RS-232 interface

1

Storage drive

Internal DVD +/-RW burner

Operating system

Microsoft

®

WINDOWS

®

7

Dimensions (W x D x H)

417 x 246 x 303 mm (16.4 x 9.7 x 11.9 in.)

Weight

Typ. 14 kg (31 lb.)

Environmental specifications
Operating temperature

0 to +50 °C, down to -20 °C with prewarmed unit

Storage temperature

-20 to +70 °C

Humidity

10 to 80 % non cond., 5 to 95 % rel. humidity

Vibration

3)

EN 60068-2-6, EN 60721-3-2 class 2M2

Shock

3)

EN 60068-2-27

1)

Please find current specifications in the latest price list

2)

Depends on the system configuration. Examples:

• DEWE-2601 with 6x DEWE-ORION-1616-500 could stream 80 MB/s to the harddisk

• DEWE-2600 with 4 x DEWE-ORION-1624-200 + 2x DEWE-CAM01 could store 70 MB/s

3)

Tested with Solid State Disk

Choose from three models

Add your choice of signal conditioning,
A/D board(s) and software to complete these systems

Additional interfaces and sensors

Measurements are not limited to just classic analog and digital signals. Please find further detailed information to
expand your system in the chapter “Components”.

Needed to complete the system

DEWE-ORION “A/D Boards” offer simultaneous sampled
analog inputs, synchronous digital I/Os, high-performance
counters and high-speed CAN interfaces. DAQP- or MDAQ
signal amplifiers and software are needed as well.

Options to expand the system

Add further “Interface Cards” like ARINC-429, 1553, PCM
telemetry, FireWire and analog output or special “Sensors”
like synchronized Video, industrial encoders (RIE-360) or
GPS.

DEWESoft

DAQP/MDAQ

A/D card

ARINC

VIDEO

VGPS

Advertising