Ac/dc/ir, Hipot, Tester – Atec Chroma 19071 User Manual

Page 2: Chroma ate inc, Specification application order information, Panel description

Advertising
background image

7

8

11

10

9

12

All specifications are subject to change without notice.

Developed and Manufactured by:

CHROMA ATE INC.

Head Office:
43, Wu-Chuan Road, Wu-Ku lnd. Park,
Wu-Ku, Taipei Hsien, Taiwan
TEL: +886-2-2298-3855
FAX: +886-2-2298-3596
http://www.chromaate.com

U. S. A.
7 Chrysler Irvine
CA 92618
TEL: +1-949-421-0355
FAX: +1-949-421-0353
Toll Free: +1-800-478 2026

Distributed by:

Worldwide Distribution and Service Network

19071/19072/19073-2004-02-1000

Europe
Max Planckstraat 4
6716 BE Ede
The Netherlands
Tel: +31-318-648282
Fax: +31-318-648288

China
8F, No.4, Nanyou Tian An
Industrial Estate Shenzhen,
China
Post Code: 518052
Tel: +86-755-

2664-4598

Fax: +86-755-

2641-9620

19071

AC Hipot Tester

19073

AC/DC/IR Hipot Tester

A190701 Remote Control Box

A190702 40kV Test Probe

Production testing of appliances, instruments

and information technology equipment in

accordance with UL, IEC, TUV and other

standards such as EN 60335, EN 60950,

EN 61010, CSA C22.2 No.1010.1, UL 3111

and UL1950

Transformer electrical safety testing

Electric motor safety testing

Variety of electrical components

Testing of electronic components

Specification

Application

Order Information

Model

19071

19073

Mode

ACV

ACV/DCV/IR

Withstanding Voltage Test

Output Voltage

AC : 0.05 ~ 5kV

AC : 0.1 ~ 5kV , DC : 0.1 ~ 6kV

Load Regulation

1 % + 5V

Voltage Resolution

2V

Voltage Accuracy

1% + 5 counts

Cutoff Current

AC : 0.1~20 mA

AC : 0.1~20 mA, DC : 0.01~5 mA

Current Resolution

AC : 1µA, DC : 0.1µA

Current Accuracy

1.5% + 5 counts

Output Frequency

50/60Hz

Test Time

0.1 ~ 999 seconds, continue

Ramp up Time

0.1 ~ 999 seconds, off

Wave Form

Sine wave

Insulation Resistance

Output Voltage

- -

DC : 50 ~ 1000V

Voltage Resolution

- -

2V

Voltage Accuracy

- -

5% + 5 counts

IR Range

- -

0.1MΩ -50GΩ

IR Accuracy

≥ 500V : 1MΩ -1000MΩ± (4% + 5 counts)

1GΩ -10GΩ ± (7% + 5 counts)

- - 10GΩ-50GΩ ± (12% + 5 counts)

< 500V : 0.1MΩ -1000MΩ ± (7% + 5 counts)
< 500V : 0.1MΩ -1000MΩ ±(10% + 5 counts)

Continuity Check

Current 0.1A, 1 Ω ± 0.2Ω, On/Off

Arc Detection

Setting Mode

Programmable Setting

Detection Current

AC : 1mA ~ 15mA, DC : 1mA ~ 5mA

Minimum Pulse Width

10 µs approx

Secure Protection Function

Fast Output Cut-off

0.4 ms after NG happen

Fast DC discharge

0.2 sec.

Ground Fault Interrupt (GFI)

0.5mA ± 0.2mA AC (Low), 5mA ± 2mA AC (High), Close

Panel Operation Lock

Present password

Continuity Check

Current 0.1A, 1Ω ± 0.2Ω, On/Off

GO/ NG Judgment

Indication, Alarm

Go:Short sound ;NG:Long sound

Data Hold

Last tests data memories

Step Hold

Step signal trigger On/Off

Memory Storage

10 tests setups with 60 steps per setup

General

Operation Environment

Temperature : 0 ~ 40˚C

Humidity : ≤ 80% RH

Power Consumption

No load : < 60W

With rated load : 300W max.

Power Requirement

100V/120V/ 220V AC ±10%, 240V AC +5%~ -10%,

50/60Hz

Weight

12kg

Dimension(W X H X D)

270 X 100 X 350mm

AC/DC/IR

.....

Hipot

.....

T

ester

..........................

1. LINE Switch

2. Window Display

3. Reset Button

4. Start Button

5. Function Keys F1~F4

6. Function Key Display Area

7. High Voltage Output Terminal

8. Common Test Terminal

9. Test Indicator

10. Fail Indicator

11. Pass Indicator

12. Calibration Switch

13. Status Line

14. Remote Control

15. LINE Voltage Selector

16. Power Cord Receptacle

17. Earth Ground Terminal

18. Continuity Check

19. Fan

20. Update Switch

Panel Description

1

6

5

4

3

2

16

15

13

17

18

14

19

20

Advertising
This manual is related to the following products: