MODEL 19032/19032-P

Electrical Safety Analyzer

Key Features :

AC/DC/IR/GB/LC five instruments in one

Function test up to 20A

Programmable voltage output and limit

value

OSC open/short check

Flashover detection

Human protection circuit

Multi-scan device support dynamic leakage

current test

Standard RS232 interface

Optional GPIB interface

Large LCD panel

Front panel lockout function

Support PC software

UL/TUV/CE

Key Features 19032-P :

500VA output

Floating output , compliance with EN50191

USB interface, compatible with USB TMC

GFI human body protection circuit

CE certification (only)

General Electrical Safety Testing Solution
Electrical safety testing is one of the major

item in the electrical product quality tests.

All electrical products consisting of adapter,

SMPS, charger, house appliance, information

technology product and video product are

required to perform electrical safety tests.

The 19032 series combines Hi-Pot, IR, GB,

LC/ALC/DLC and Dynamic Function Test. That

can save 50% of production line space without

purchasing several Hi-Pot testers , 19032 is

able to increase efficiency of electrical safety

test during manufacturing and reduce the risk

on testing.

Open/Short Check (OSC)

Patent No. : 254135

All manufacturers have to solve the problems of

error connections and unconnected test cables

caused by the production line testers.Chroma

19032 equipp with the up-to-date open/short

check function (OSC) for product testing.It can

free the tests from such problem.

Twinport

TM

Function

USA Patent No.: US6504381

The key factor affecting the efficiency of

manufacturing is the efficiency for electrical

safety test. Twinport function can lower the time

for safety test, and safety workstation will no

longer be a bottleneck in production line.

Product Application
The 19032 can be applied to versatile

tests of electrical products which include

quality assurance sampling inspection test,

manufacturing test and development validation.

• Power cord

• Adapter, SMPS

• House appliance

• Information technology product

• Medical equipment

• Lab/testing equipment

• EMI FILTER

EN50191 Floating Output Function
The leakage current of any ground terminal

should be lower than 3.5mA when operating

Floating output function. Therefore, the

operator who near to potential ground terminal

can avoid electrical hazard.