3030/3030A

Dranetz-BMI 3030A Specifications The 3030A is a rugged,
precision instrument. Dranetz-BMI maintains special calibration
stations to ensure continued accuracy.

Specifications

Parameter

Specifications

Voltage measurements

Single-phase, split single-phase, three-phase wye, three-phase delta

0.1 Vrms - 600.0 Vrms (±1000.0 Vpk)

Accuracy at 50/60 Hz: ±0.1% reading ±0.01% full scale

Useful bandwidth: DC - 3 kHz

Current measurements

Optional A-115 probe 1.0 Arms - 60.0 Arms

Accuracy at 50/60 Hz: ±0.1% reading ±0.03% full scale

Useful bandwidth: 50 Hz - 1 kHz

Optional A-116 probe

10.0 Arms - 600.0 Arms

Accuracy at 50/60 Hz: ±0.1% reading ±0.01% full scale

Useful bandwidth: 50 Hz - 3 kHz

Optional A-120 probe

10.0 Arms - 3000.0 Arms

Accuracy at 50/60 Hz: ±0.1% reading ±0.01% full scale

Useful bandwidth: 30 Hz - 3 kHz

Optional A-121 probe

0.1 Arms - 20.0 Arms

Accuracy at 50/60 Hz: ±0.2% reading ±0.02% full scale

Useful bandwidth: 45 Hz - 3 kHz

Frequency

Fundamental range 25 - 65 Hz

Environment

Operating: 41°F to 122°F

+5°C to +50°C

Storage: -40°F to 167°F

-40°C to +75°C

Humidity 10% - 90% non-condensing

Battery

15 minutes operation-3 hours full recharge

PC Software package

PowerPlot

Packages

Includes demand, harmonics, storage, neutral options

Latest released version

EPU A1.0 : CPU C : SPU A2.0

Accuracy specifications at 20°C, 50/60 Hz, 5% F.S. to 60% F.S. Temperature coefficient ±200ppm/°C,
drift less than 10 ppm/day full scale, noise less than 0.05% full scale, resolution ±0.5 display count.

Login | Special Offers

Quick Tech Tips

Source Stiffnes

...more

So How Do I Get PES

To Recognize My Modem?

...more

Quick FAQ's

How do I do the factory

reset on my 658?

...more

Can you tell me more

about the 3100 PQPager?

...more

All contents of this website © 2009 Dranetz-BMI. All rights reserved.

Comments are welcome at

[email protected]

.

Visit Dranetz-BMI's other websites and sister company's

Signature System

|

Electrotek Concepts

|

Daytronic Corp.

Dranetz-BMI is a Global Power Technology, Inc. Company

Dranetz-BMI Product Applications

http://www.dranetz-bmi.com/support/legacy_detail.cfm?prod=5

1 of 1

05/10/2009 15:11

Advertising