* Maximum power delivered at high source range

CONVERTIBLE AMPLIFIERS

Current Mode

Convertible Source AC Ranges

Convertible Source DC Ranges

Power

Resolution AC Ranges

Resolution DC Ranges

6 X 0.5, 1.0 A rMs (L-N)

6 X 0.354, 0.707 A dc

6 X 75VA / 75 W

0.0001 A

0.0001 A

3 X 0.5, 1.0, 2.0 A rMs (L-N)

3 X .354, 0.707, 1.41 A dc

3 X 150VA / 150 W

0.0001 A

0.0001 A

1 X 1.5, 3.0, 6.0 A rMs (L-N)

s1

ǁ s2ǁ s3

1 X 1.06, 2.12, 4.24 A dc

s1

ǁ s2ǁ s3

1 X 450VA / 450 W

s1

ǁ s2ǁ s3

0.001 A

0.001 A

Current Transient Mode

Convertible Source AC Ranges

Convertible Source DC Ranges

Power

Resolution AC Ranges

Resolution DC Ranges

6 X 0.75, 1.5 A rMs (L-N)

6 X 0.53, 1.06 A dc

6 X 97.5VA / 97.5 W

0.0001 A

0.0001 A

3 X 0.75, 1.5, 3.0 A rMs (L-N)

3 X 0.53, 1.06, 2.12 A dc

3 X 195VA / 195 W

0.0001 A

(0.0001 A) @ 0.53, 1.06 A dc

(0.001 A) @ 2.12 A dc

1 X 2.25, 4.5, 9.0 A rMs (L-N)

s1

ǁ s2ǁ s3

1 X 1.59, 3.18, 6.36 A dc

s1

ǁ s2ǁ s3

1 X 585VA / 585 W

s1

ǁ s2ǁ s3

0.001 A

0.001 A

Voltage Mode

Convertible Source AC Ranges

Convertible Source DC Ranges

Power

Resolution AC Ranges

Resolution DC Ranges

6 X 75, 150V rMs (L-N)

6 X 106, 212V dc

6 X 75VA/ 75W

0.01 V

(0.01 V) @ 106V dc

(0.1 V) @ 212V dc

3 X 75, 150, 300V rMs (L-N)

3 X 106, 212, 424V dc

3 X 150VA / 150 W

0.01 V

(0.01 V) @ 106V dc

(0.1 V) @ 212, 424V dc

1 X 150, 300, 600V rMs (L-L)

s1 & s2

1 X212, 424, 848V dc

s1 & s2

1 X 300VA / 300 W

s1 & s2

0.01 V

0.1 V dc

ENHANCED CURRENT AMPLIFIERS

AC Ranges

DC Ranges

Power

Resolution AC Ranges

Resolution DC Ranges

6 X 8.75, 17.5, (35)* A rMs (L-N)

6 X 5.83, 11.7, (23.3)* A dc

6X 87.5VA / 87.5 W;

(6 X 131.25VA /131.25 W)*

0.001 A

(0.001) A @ 5.83 A dc

(0.01) A @ 11.6, (23.3)* A dc

3 X 8.75, 17.5, 35,(70)*

A rMs (L-N)

3 X 5.83, 11.7, 23.3,(46.6)* A dc

3 X 175VA / 175 W;

(3 X 262.5VA /262.5 W)*

(0.001) A @ 8.75, 17.5, 35 A rMs

(0.01) @ (70)* A rMs

(0.001) A @ 5.83 A dc

(0.01) A @ 11.7, 23.3, (46.6)* A dc

1 X 8.75, 17.5, 26.25,52.5, 105,

(210)* A rMs (L-N)

s1

ǁ s2ǁ s3

1 X 5.83, 11.7, 17.5, 35,70, (140)*

A dc

s1

ǁ s2ǁ s3

1 X 525VA / 525 W;

(1X787.5VA/787.5 W)*

s1

ǁ s2ǁ s3

(0.001) A @ 8.75,

17.5, 26.25 A rMs

(0.01) A @ 52.5, 105, (210)* A rMs

(0.001) A @ 5.83 A dc

(0.01) A @ 11.7, 23.3, 35, 70,

(140)* A dc

Ac Amplitude Accuracy @ 50-60 Hz

@ 20° - 30° c

Typical

Guaranteed

0.02% of reading +

.01% of range

0.09% of reading +

.04% of range

distortion @ 50/60Hz V & I sources Total

Harmonic distortion (THd)

Typical

Guaranteed

<0.02%

<0.1%

Phase Angle @ 50/60 Hz

Range

Accuracy

Resolution

(+359.9°) -(0°) -

(-359.9°)

± 0.25°

± 0.1°

Frequency

Bandwith

Range

Resolution

dc - 3kHz at Full

Power

dc, 0.1 Hz - 2.0 kHZ

continuous Full Load

0.001 Hz

convertible source in current Mode @ 20° - 30° c

Guaranteed

<0.5%

Accuracy

Typical

@ 20° - 30° C

@ 0° - 50° C

0.5 ppm

1.5 ppm

10 ppm