Atec Biddle-DET3-2 User Manual

Det3 contractor series, Terminal earth/ground resistance testers

Advertising
background image

DET3 Contractor Series

3-Terminal Earth/Ground Resistance Testers

2 and 3 point testing

ART (Attached Rod Technique)
testing capability

User selectable test voltage (25/50 V)

Choice of digital or analog display

Warning indicators prevent test failure

IP54 rated

Complete with leads, stakes and
rugged carry case

Simple one button operation

DET3 Contractor Series

Earth/Ground Resistance Testers

DESCRIPTION

Megger’s already popular 3-terminal ground testing

instrument family includes the following models:

Model

Description

DET3TD

For basic requirements it provides digital

ground testing and bond testing capabilities

DET3TC

The revolutionary new model with the

capability of testing on-site grounds without

disconnecting the utility connection.

The DET3TC includes a

current measuring function

for ART (Attached Rod

Technique) testing

capabilities. With this

added function, on-site

grounds can be tested

separately without having

to remove the utility

connection (as explained

further in this document).

The complete kit of

instrument, test leads,

stakes, batteries and

calibration certificate is

delivered in a tough

polypropylene carry case

– everything you need to

start testing in one package. Optional terminal adapters

are available for acceptance of a variety of test leads.

All models are rated to IP54, making them truly outdoor

instruments. They are designed to meet stringent safety

standards and are rated CAT IV 100V. The ground testers

have been designed to be easy to use – a large selector

switch makes selection of 2 or 3 pole tests easy with

gloved hands – and the design makes the fitting of

shorting links to perform 2-pole tests a thing of the past. A

large, clear, easy to read LCD and thumb-sized test button

also make the instruments particularly well suited to the

outdoor conditions of ground testing. In addition to this

ease of use feature, the ground tester automatically checks

the connection and conditions of the P spike, C spike, and

also the level of ground noise, indicating the status on the

display. The instruments also include a voltmeter to enable

measurement of ground voltage. They can measure

resistance from 0.01 ohms to 2 k

. Also, to allow accurate

testing in noisy environments, the instruments are capable

of rejecting noise up to 40V peak to peak.

The Megger ground testers are powered by eight AA

batteries which are widely available and also give

excellent testing time – the status of these batteries is

given by a bar graph on the LCD, allowing the operator to

decide when to change the batteries before they expire.

By using the optional ICLAMP with the DET3TC, the user

can augment the traditional fall-of-potential measurement

method with ART (Attached Rod Technique), which allows

electrode testing without disconnection and also leakage

current measurements down to 0.5 mA.

Using ART method with the DET3TC
to test commercial ground without
disconnecting the system

Advertising