Atec AEMC-6470 User Manual

Multi-function ground resistance tester model 6470, Features, Specifications

Advertising
background image

1

www.aemc.com

Technical Assistance (800) 343 -1391

Model 6470

GROUND RESISTANCE TESTERS

Multi-Function Ground Resistance Tester
Model 6470

Measure ground
resistance, soil
resistivity and
bonding
resistance
with one
instrument!

NEW!

NEW!

NEW!

NEW!

NEW!

Model 6470 includes meter,

NiMH batteries, optical USB cable,

DataView

®

software,

external battery charger,

power adapter 110/240V (line)

and user manual.

Features

3-Point Fall-of-Potential measurement with
manual or automatic frequency selection

3-Point earth coupling measurement

Automatic frequency scan from 40 to 513 Hz
for optimum test accuracy in electrically noisy
environments

Selectable test voltage of 16 or 32V with
up to 250mA

4-Point soil resistivity measurement with
automatic calculation of Rho (

ρ

) and user

selection of the Wenner or Schlumberger
test method

2- and 4-wire DC resistance measurement
(Bond testing) with automatic polarity reversal

Automatic measurement of auxiliary electrodes
resistance

Auto-off power management

Automatic recognition of all electrode
connections and their resistance value

Stores up to 512 complete test results

Optically coupled USB Communication

Remote set up and operation of all measure-
ments using DataView

®

software supplied

Automatic report generation

Rechargeable NiMH batteries from wall charger
or vehicle power

Rugged dustproof and rainproof field case –
IP54 rated in closed position

IEC 61557 parts 4 and 5 compliant

Includes DataView

®

software for data storage,

real-time display, analysis, report generation
and system configuration

SPECIFICATIONS

MODEL

6470

ELECTRICAL

3-Point Measurement

Range (Auto-Ranging)

0.01 to 99.99kΩ

Resolution

0.01 to 100Ω

Test Voltage

16 or 32V selectable

Resistance Measurement Frequency

40 to 513Hz selectable or automatic selection

Test Current

Up to 250mA

Accuracy

±2% of Reading + 1ct

Soil Resistivity 4-Point Measurement

Test Method

Wenner or Schlumberger selectable with

automatic calculation of test results

displayed in Ω-meters or Ω-feet

Range (Auto-Ranging)

0.01 to 99.99kΩ

Resolution

0.01 to 100Ω

Test Voltage

16 or 32V selectable

Frequency

73, 91.5, 101, 110 or 128Hz selectable

External Voltage Measurement

Range (Auto-Ranging)

0.1 to 65.0V

AC

/

DC

– DC to 500Hz

Accuracy

2% of Reading + 2cts

Resistance Measurement (Bond Testing)

Measurement Type

2-Point or 4-Point user selectable

Range (Auto-Ranging)

2-Point 0.01 to 99.9kΩ; 4-Point 0.001 to 99.99kΩ

Accuracy

±2% of Reading + 2cts

Test Voltage

16V

DC

Test Current

200mA max

Data Storage

Memory Capacity

512 test results

Communication

Optically isolated USB

Power Source

Eight 1.2V NiMH rechargeable batteries

Recharging Source

110/120 50/60Hz external charge with

18V

DC

, 1.9A output or 12V

DC

vehicle power

Advertising