LOOP ANTENNAS

S

PECIFICATIONS

F

REQUENCY

R

ANGE

I

NPUT

P

OWER

I

MPEDANCE

S

IZE

C

ONNECTOR

T

YPE

L

OOP

B

ASE

ALA - 130/RS

1 kHz - 30 MHz

N/A

50 ohm

12" dia

6" x 4"

BNC Female

Active

ALA - 1030/RS 10 kHz - 30 MHz

N/A

50 ohm

24"x24"

6" x 4"

BNC Female

Active

PLA - 130/A

1 kHz - 30 MHz

1 kW

50 ohm

12" dia

6" x 4"

N Female

Passive

PLA - 205/B

20 Hz - 5 MHz

5 Watts

50 ohm

24"x24"

4" x 3"

BNC Female

Passive

PLA - 1030/B

10 kHz - 30 MHz

5 Watts

50 ohm

24"x24"

6" dia

BNC Female

Passive

PLA - 2050/A

20 Hz - 100 kHz

N/A

N/A

5.2" dia

3" x 2.5" BNC Female

Passive

PLH - 2050/A

20 Hz - 100 kHz

5 Amps

N/A

4.7" dia

4.7" dia

Banana Jack

Passive

Options

1. 10-foot RF cable with ferrite sleeves

3) Carrying Case

2. Tripod, TP-5 or TP-3

ALA-130/RS

PLA-130/A

ARA TECH offers two different models (ALA-130/A and ALA-

1030/B) of active loop antennas, three different models (PLA-

130/A, PLA-1030/B, and PLA-205/B) of passive loop
antennas, and two different pairs (

PLA-2050 & PLH-2050 and

PLA-451 & PLH-450) of loop sensors or field pick up coils and
radiating loops.

The

PLA-130/A and ALA-130/RS are designed for the

shielded room testing requirements per MIL-STD 285 and NSA
test standard 65-6. The

PLA-130/RS is capable of handling 1

kW input power while the

ALA-130/RS provides the dynamic

range required for shield room attenuation measurements. The
ALA-130/RS and PLA-130/A are sold together as a set known
as the

APL-130/RS.

The

PLA-1030/B is a single band passive loop antenna for

immunity or emission testing.

The

PLA-205/B is optimized for generating fields in the low

end of the frequency band from 20 Hz to 5 MHz. It can also be
used for emission testing at low frequencies. When used with
our extremely sensitive

BBH series receive antennas, it

provides the best combination for testing shielding
effectiveness in the 20 Hz to 5 MHz band.

All loop calibrations are made relative to a 50 ohm load. Active
and passive loops (except field generating coils

PLH-450 and

PLH-2050 and field pick-up coils PLA-2050 and PLA-451) are
individually calibrated in accordance with procedures specified
in IEEE-291 section 2.3.1.