Atec AR-CI00400A User Manual

Page 2

Advertising
background image

Page 2 of 2

RF Amplifier Specifications

Frequency range

10 kHz to 400 MHz

Power rating

100 Watts Nominal

1dB compression

75 Watts Nominal

Harmonic Distortion

-20dBc at 50 Watts

Mismatch tolerance

100% of rated power without
fold back. Will operate without
damage or oscillation with any

magnitude of source and load
impedance.

Gain

51dB minimum

Connections

RF Out

Type N (front)

Monitor Port In

Type N (front)

Signal Generator Out

Type N (rear)

Directional Coupler In

Type N (rear)

Amplifier Out/In

Type N (rear)

Pulse In

BNC (rear)

Communication

GPIB (IEEE 488) (rear)

Directional Coupler Fwd Out

Type SMA (rear)

Directional Coupler Fwd In

Type SMA (rear)

Directional Coupler Rev Out
(with Option 1)

Type SMA (rear)

Directional Coupler Rev In
(with Option 1)

Type SMA (rear)

Monitor Port Out

Type SMA (rear)

Monitor Port In

Type SMA (rear)

Power Meter Calibration Port Out

Type SMA (rear)

General

Power 115/230

VAC

50/60 Hz, single phase 16A

Breaker

2 pole, 20A

Cooling

active cooling, air ventilation

Environmental conditions

10°C - 40°C

Dimensions,

50.3 x 42.2 x 52.1 cm
19.8 x 16.6 x 21.7 in

Weight

22.7 kg (50.0 lb)

Weight CI00400AM5

17.3 kg (38.2 lb)

Control Software

emcw

ar

e® Software Suite

PC Requirements

Computer

2GHz Single Core Processor

Operating system

Windows XP, Windows Vista,
Windows 7

RAM

1 GB Minimum

Screen Resolution

1024 x 768

Ports

2 available USB 2.0 ports

Options

1

Additional power head to add the ability to monitor
reverse power

2

Data acquisition card.

3

Laptop PC with software preinstalled

4

Amplifier removed; requires use of external amplifier

MODEL CONFIGURATIONS

MODEL DESCRIPTION

CI00400AM1

Includes Option 3

CI00400AM2

Includes Options 2 and 3

CI00400AM3

Includes Option 2

CI00400AM4

Includes Option 1

CI00400AM5

Includes Option 4

CI00400AM6

Includes Options 1 and 4

CI00400AM7

Includes Options 1 and 3

ACCCESSORY KITS

Application Model

Description

IEC 61000-4-6

BCI Clamp

50 System

TK1000

Conducted immunity test kit containing all the attenuators, injection

probes, calibration fixtures, calibration resistors, and termination
resistors necessary for IEC testing.

IEC 61000-4-6

BCI Clamp

150 System

TK1001

Conducted immunity test kit containing all the attenuators, injection
probes, calibration fixtures, calibration resistors, and termination
resistors necessary for IEC testing.

IEC 61000-4-6

EM Clamp

50 System

TK1002

Conducted immunity test kit containing all the attenuators, injection

probes, calibration fixtures, calibration resistors, and termination
resistors necessary for IEC testing.

MIL-STD-461

DO160

TK2000

Conducted immunity test kit containing all the attenuators, injection
probes, calibration fixtures, calibration resistors, and termination
resistors necessary for MIL-STD-461 and DO160 testing.

Automotive

TK3000

Conducted immunity test kit containing all the attenuators, injection
probes, calibration fixtures, calibration resistors, and termination
resistors necessary for automotive testing.

Advertising