Atec AR-CI00401A User Manual

Atec Equipment

Advertising
background image

Approved for public release by AR RF/Microwave Instrumentation

092412

160 School House Road Souderton, PA 18964-9990 • 215-723-8181 • www.arworld.us

Page 1 of 2

Model CI00401A, M1, M2

RF Conducted Immunity System

150 Watts

100 kHz–400 MHz

Complete Testing Solutions to the following standards:

ISO 11452-4

GMW 3097

ES-XW7T-1A278-AC

DC-11224

BMW GS95002

Peugeot B217110

Renault 36-00-8081-G

IEC 61000-4-6

Other automotive standards


The Model CI00401A is a fully self-contained state of the art system

designed to test RF Conducted Immunity. The CI00401A contains all the
instruments needed to perform conducted immunity testing for automotive

and IEC specifications. The system contains a signal generator, three channels of power monitoring, 150W AR amplifier
100 kHz to 400 MHz, directional coupler, and emcw

ar

e® control software. Everything is contained in a single housing,

which eliminates setup issues. This system provides the versatility needed for every test laboratory and equipment

manufacturer. The RF amplifier and the signal generator can be used independently of the system. If special needs arise
or standards were to change, a larger amplifier can be connected to the system. The use of spectrum analyzers and
monitoring equipment may also be controlled by the software.

The export classification for this equipment is EAR99. These commodities, technology or software are controlled for export
in accordance with the U.S. Export Administration Regulations. Diversion contrary to U.S. law is prohibited.

Internal Test Specifications (See Note 1)

ISO 11452-4
GMW 3097
ES-XW7T-1A278-AC
DC-11224
BMW GS95002
Peugeot B217110
Renault 36-00-8081-G
IEC-61000-4-6
Other automotive standards

Signal Generator Specifications

Frequency range
resolution

9 kHz to 1.2 GHz
1Hz

Power range

resolution

-140 to +13 dBm

0.1 dB

Modulation

AM, FSK. FM, Phase, External Pulse

Power Meter Specifications (See Note 2)

Power heads

3

Type

Diode

Frequency

10 kHz to 8 GHz

Range

-60 to +20 dBm

RF Amplifier Specifications

Frequency range

100 kHz to 400 MHz

Power rating

150 Watts Minimum

1dB compression

120 Watts Minimum

Harmonic Distortion

-20 dBc at 120 Watts

Mismatch tolerance

100% of rated power without

fold back. Will operate without
damage or oscillation with any
magnitude of source and load
impedance.

Gain

52 dB minimum

NOTE 1: Specifications can be met using AR-specified external accessories (injection probes, monitor probes, cal fixtures, CDN’s,

attenuators, etc.) Contact AR for further information.

NOTE 2: The use of a spectrum analyzer may be necessary on some of the low level bulk current injection tests. This is especially true on

power and I/O lines with a great amount of ambient noise.