TECHNICAL DETAILS

CDNS FOR MAINS SUPPLY LINES,
TYPE M

16A M-TYPE CDN MODELS

CDN-M1/16A

For Earth conductor
- AE: 4mm safety lab connectors
- EUT: 4mm safety lab connectors
- Voltage/current max. 240V/16A
- Frequency 150kHz - 230MHz

CDN-M2N

For 2 AC/DC supply lines
- AE: IEC 320 connector
- EUT: 4mm safety lab connectors
- Voltage/current max. 240V/16A
- Frequency 150kHz - 300MHz

CDN-M2-16A S2

For 2 AC/DC supply lines
- AE: 4mm safety lab connectors
- EUT: 4mm safety lab connectors
- Voltage/current max. 1,000V/16A
- Frequency 150kHz - 80(230)MHz

CDN-M2 S2

For 2 AC/DC supply lines
- AE: 4mm safety lab connectors
- EUT: 4mm safety lab connectors
- Voltage/current max. 240V/16A
- Frequency 10kHz - 80MHz

CDN-M2/400V

For 2 AC/DC supply lines
- AE: 4mm safety lab connectors
- EUT: 4mm safety lab connectors
- Voltage/current max. 400V/16A
- Frequency 150kHz - 80(230)MHz

CDN-M2/750V

For 2 AC/DC supply lines
- AE: 4mm safety lab connectors
- EUT: 4mm safety lab connectors
- Voltage/current max. 750V/16A
- Frequency 150kHz - 80(230)MHz

CDN-M2/M3N

For 2 or 3 AC/DC supply lines
(switchable)
- AE: IEC 320 connector
- EUT: 4mm safety lab connectors
- Voltage/current max. 240V/16A
- Frequency 150kHz - 300MHz

CDN-M3N

For 3 AC/DC supply lines
- AE: IEC 320 connector
- EUT: 4mm safety lab connectors
- Voltage/current max. 240V/16A
- Frequency 150kHz - 300MHz

...

16A M-TYPE CDN MODELS (CONTINUATION)

CDN-M3 S3

For 3 AC/DC supply lines
- AE: 4mm safety lab connectors
- EUT: 4mm safety lab connectors
- Voltage/current max. 240V/16A
- Frequency 10kHz - 80MHz

CDN-M3/400V

For 3 AC/DC supply lines (L,N,PE)
- AE: 4mm safety lab connectors
- EUT: 4mm safety lab connectors
- Voltage/current max. 400V/16A
- Frequency 150kHz - 80 (230) MHz

CDN-M3/Delta

For 3 AC/DC supply lines (L1/L2/L3)
- AE: 4mm safety lab connectors
- EUT: 4mm safety lab connectors
- Voltage/current max. 3x400V/16A
- Frequency 150kHz - 80 (230) MHz

CDN-M4/PE

For 4 AC/DC supply lines
(L1/L2/L3/PE)
- AE: 4mm safety lab connectors
- EUT: 4mm safety lab connectors
- Voltage/current max. 3x400V/16A
- Frequency 150kHz - 230MHz

CDN-M4/N

For 4 AC/DC supply lines
(L1/L2/L3/N)
- AE: 4mm safety lab connectors
- EUT: 4mm safety lab connectors
- Voltage/current max. 3x400V/16A
- Frequency 150kHz - 230MHz

CDN-M5/16A

For 5 AC/DC supply lines
(L1/L2/L3/N/PE)
- AE: 4mm safety lab connectors
- EUT: 4mm safety lab connectors
- Voltage/current max. 3x400V/16A
- Frequency 150kHz - 230MHz

www.emtest.com