Atec EMCO-ETS-Lindgren-3810-2-3816_2 User Manual

Lisn / plisn, Test site hardware, Features

Advertising
background image

1

11

11

LISN / PLISN

Test Site Hardware

Features:

l

9 kHz to 30 MHz Frequency Range

l

10 A or 16 A Continuous Current Rating

l

Earth Line Choke

l

Artificial Hand Network

l

High Pass Filter

l

Choice of Plugs / Receptacles

l

Manual or Remote Switched Test Ports

Model 3810/2 LISN

ETS-EMCO’S LISN MODELS 3810/2 & 3816/2

are multi-line low pass filter networks
used for conducted emissions measure-
ment. They are placed between the
power mains and the EUT (Equipment
Under Test) to stabilize line impedance,
provide a 50 ohm RF connection, and
eliminate unwanted RF signals from the
line supply. In addition, LISNs can be
used to predict radiated emissions for
diagnostic and precompliance testing
(see page 2 sidebar).

The Model 3810/2 is designed and tested
in accordance with IEC Publication 1010,
Safety Requirements for Electronic
Measuring Apparatus. It has also received
CSA safety certification from the
Canadian Standards Association, a
further indication of ETS-EMCO's
commitment to safety.

Both model LISNs cover the frequency
spectra of 9 kHz to 30 MHz and are
designed to be used with a signal
analyzer for making FCC 15, VDE 0871 &
0875, and EN55022 conformance
measurements.

Features Models 3810/2
and 3816/2

Earth Line Choke
An Earth Line Choke is included on the
Model 3810/2 and Model 3816/2. The
choke isolates the EUT from RF ground
while maintaining a safety ground.

Artificial Hand
An Artificial Hand circuit which
conforms to EN55014 is included in both
model LISNs. The circuit is useful for
testing hand-held equipment which does
not have a connection to protective earth
ground.

High Pass Filter
A switchable high pass filter is included
on the Model 3816/2, preventing
potential overload to the analyzer and
eliminating the need to apply correction
factors to measurements.

Choice of Plugs/Receptacles
Both models are available with either
NEMA

®

, SCHUKO

®

, or British power out

connectors.

Manual and Remote Switched
Test Ports
Manual line switching is provided on the
Model 3810/2, while both manual and
remote switching are included on the
Model 3816/2. In the remote switching
mode, the selected line (A or B) is termi-
nated in a 50 ohm load when power has
not been applied to the mains, permitting
measurement of the noise floor.

Standard Configuration

l

LISN assembly

l

Individually calibrated per ANSI C63.4.
Actual insertion loss and impedance data
and a signed Certificate of Calibration
included in Manual.

Options

MP4 Cord Loom
Provides a repeatable method for looping
excess cord in serpentine fashion, per MP4.

Model 3810/2, 3816/2

Information presented is subject to change as product enhancements are made. Contact ETS Sales Department for current specifications.

Information presented is subject to change as product enhancements are made. Contact ETS Sales Department for current specifications.

Information presented is subject to change as product enhancements are made. Contact ETS Sales Department for current specifications.

Information presented is subject to change as product enhancements are made. Contact ETS Sales Department for current specifications.

Information presented is subject to change as product enhancements are made. Contact ETS Sales Department for current specifications.

3/00 - 2k S © 2000 ETS-EMCO REV A

3/00 - 2k S © 2000 ETS-EMCO REV A

3/00 - 2k S © 2000 ETS-EMCO REV A

3/00 - 2k S © 2000 ETS-EMCO REV A

3/00 - 2k S © 2000 ETS-EMCO REV A

USA:

Tel +1.512.835.4684
Fax +1.512.835.4729

FINLAND:

Tel +358.2.8383.300
Fax +358.2.8651.233

ONLINE:

[email protected]
http://www.emctest.com

Advertising