Accessories

Rack mount kit without handles (Option 1CM)

Adds a rack mount (5063-9217) and rail kit (E3663AC) for use

without handles.

Rack mount kit with handles (Option 1CP)

Adds a rack mount (5063-9237)

1

and rail kit (E3663AC) for use

with standard supplied handles.

Configuration Details

Selecting the correct mixer-test configuration:

Most mixer or converter test applications require Options 014, 080,

and 082 for conversion loss/gain, or Options 014, 080, 081 and

083 for conversion loss/gain and phase/delay measurements. If

you want to create and automate your own custom frequency-

offset measurements (for example, intermodulation distortion),

you may only need Options 014 and 080. For converters that

require input power below -27 dBm, or for devices that have a

large amount of LO feedthrough (like an unfiltered mixer), Option

UNL, which adds source attenuators, is highly recommended.

Besides allowing lower input power levels, these attenuators

improve the isolation between the PNA’s internal source and

LO leakage signals, helping to prevent source-unleveled errors.

For devices that put out signals near or above the receiver’s

compression levels (which varies between –3 and +5 dBm,

depending on the model and frequency), Option 016 is recom-

mended, which adds receiver attenuators. Finally, Option 010,

which adds time-domain analysis, is very useful for gating out

unwanted, time-delayed responses which often occur when

measuring mixers.

PNA Series Network Analyzer

4-port measurement application (Option 550)

Adds multiport analyzer mode to any PNA network analyzer

with Option 014 configurable test set, which enables full

4-port error correction and measurement capabilities using an

external test set. Only standard measurement class is available

in the multiport analyzer mode.

N-port capabilities (Option 551)

Adds multiport analyzer mode to any PNA network analyzer

with Option 014 configurable test set, which enables full

N-port error correction and measurement capabilities using

an external test set. Only standard measurement class is

available in the multiport analyzer mode.

Pulse, antenna, mm-wave

Pulsed-RF measurement capability (Option H08)

Provides software to set up and control pulsed-RF measurements

with point-in-pulse capability. The software sets the coefficient

of the PNA’s digital-IF filter to null out unwanted spectral

components, enables the IF gates provided with IF access

(Option H11), and controls selected Agilent pulse generators.

It can be run on the PNA or an external computer. A “.dll” file

containing the IF-filter algorithms is included for automated

pulsed-RF testing. The pulsed application is configured to work

with the Agilent 81110A series pulse generator.

For more detailed information regarding pulsed measurement

capabilities with the microwave PNA refer to the Agilent Web

site

www.agilent.com/find/pna and download the PNA Series

MW Network Analyzers Configuration Guide for Pulsed

Measurements, literature number 5989-7913EN.

IF access (Option H11)

Provides hardware to enable antenna, point-in pulse, and

broadband millimeter-wave measurements to 110 GHz. For

each of the MW PNA’s measurement receivers, IF gates

(enabled with pulsed measurement capability, Option H08) and

external IF inputs are added. In addition, access to the PNA’s

internal RF and LO source is provided for remote mixing

applications. For basic antenna measurements, only Option H11

is necessary. Pulsed antenna applications also require the

pulsed measurement capability (Option H08). Broadband

measurements to 110 GHz, also requires an N5260A

millimeter-wave test set controller.

Note: Use external IF access for up to 20 dB more sensitivity

when making antenna measurements with a remote mixing

configuration. Add Option H08 (Pulsed-RF Measurement

Capability) to enable advanced pulsed measurements. Or

upgrade to a broadband (10 MHz to 110 GHz) VNA system

simply by purchasing an N5260A controller test set with test

heads (Option 110, 120, or 130).

1. The 5063-9237 kit assumes you have the standard handles shipped

with the instrument. If you do not have handles, order a 5063-9224 kit.

5