Atec AEMC-ML912 User Manual

Dual channel miniflex, Model ml912, Data loggers simple logger

Advertising
background image

46 www.aemc.com

Technical Assistance (800) 343-1391

featureS

Includes two integral MiniFlex

®

flexible

current probes that will measure from

0.5A to 1000A TRMS with 0.1A

resolution

Dual range 100/1000A user selectable

per channel

64 samples per cycle

Programmable storage rates from 8

every second to 1 every day

4 user selectable storage modes

Stores up to 240,000 measurements

in non-volatile memory

Powered by standard

Alkaline batteries

Lightweight, compact, fits anywhere

5 LED indicators quickly and clearly

display logger status

Includes FREE DataView

®

software

for data storage, real-time display,

analysis and report generation

Isolated USB 2.0 communication

cable included

EN 61010-1; 600V CAT IV,

1000V CAT III

applicationS

Single and Split phase load monitoring

Neutral and ground current monitoring

Intermittent problem detection

Harmonic current monitoring using

DataView

®

software

Machine load monitoring

Fault current detection

Load profiling

DATA LOGGERS

Simple Logger

®

II TRMS Current

SpecificationS

MODEL

ML912

electRIcal
Channels

Two

Input

Captive MiniFlex

®

AC Current Flexible Sensors

Range

0.5 to 100A

ac

5 to 1000A

ac

Accuracy

(50/60Hz)

0 to 1A unspecified

1 to 100A:

±(1% of Reading + 0.5A)

0 to 5A unspecified

5 to 1000A:

±(1% of Reading + 1A)

Resolution

0.1A

Sample Rate

64 samples/cycle

Storage Rate

Programmable from 8 every second to 1 every day

Storage Modes

Start/Stop, FIFO, Extended Recording Mode (XRM

)* and Alarm

Recording Length

15 minutes to 8 weeks, programmable using DataView

®

Memory

240,000 measurement (512KB)

The recorded data is stored in non-volatile memory

and will be retained even if the battery is low or removed.

Communication

USB 2.0 optically isolated

Power Source

2 x 1.5V AA-cell Alkaline batteries (included)

Battery Life

100 hrs to >45 days

(dependent on storage rate/recording length)

MechanIcal
Dimensions

4.95 x 2.75 x 1.28" (136 x 70 x 32mm) w/o Sensor

Max Conductor

Size

Sensor: 6" (152mm)/Cable: 6 ft (2m)

weight

(with battery)

8.67 oz (245g)

Case

UL94-V0

Vibration

IEC 68-2-6 (1.5mm, 10 to 55Hz)

Shock

IEC 68-2-27 (30G)

Drop

IEC 68-2-32 (1m)

catalog no.

DescRIptIon

2126.37

Simple Logger

®

II Model ML912 (2-Channel, TRMS, MiniFlex

®

, 100/1000A

ac

, DataView

®

software)

R ATIN G

SAFETY

Dual channel MiniFlex

®

Model Ml912

Two channel AC recording logger

incorporates two selectable

measurement ranges

Advertising