Atec AEMC-8435 User Manual

Powerpad, Iii model 8435, Product includes

Advertising
background image

www.aemc.com

Technical Assistance (800) 343-1391

POWER QUALITY ANALYZERS, METERS & LOGGERS

Three-Phase Power Quality Analyzer

Memory capacity of 2GB

for trend data storage:

Up to 50 captured

snapshots, 210 captured

transients, 1 inrush

and 10,000 alarm events

PowerPad

®

III Model 8435

PRODUCT INCLUDES

Extra large tool bag, accessory
pouch, 5 ft USB cable, five 10 ft black
voltage leads with alligator clips,
110V US power cord, four water-tight
AmpFlex

®

A196-18-BK (included with

Cat. #2136.42 only), NiMH battery,
SD-Card (2GB), twelve color-coded
input ID markers, quick start guide,
and a USB stick containing DataView

®

software and user manual.

8435 Kit

3

3

W

AR

R AN

T

Y

YEAR

(upon registering)

SPECIFICATIONS

MODEL

8435

ELECTRICAL

Sampling Frequency

256 samples/cycle

Data Storage

2GB SD Card for trend recording;

Additional separate 12.5MB partitioned memory for

snapshots, transient/inrush & alarms

Voltage (TRMS)

Phase-to-Phase: 2000V

Phase-to-Neutral: 1000V

Voltage Ratio: up to 500kV

Current (TRMS)

MN Clamp: 0 to 6A/120A or 0 to 240A

SR Clamp: 0 to 1200A

MR Clamp: 0 to 1000A

ac

, 0 to 1400A

dc

MiniFlex

®

: 10 to 1000A

AmpFlex

®

: 10 to 6500A

(

1

)

Current Ratio: 10mA to 50kA

Frequency (Hz)

40 to 69Hz

Other Measurements

kW, kVAR, kVA, PF, DPF, kWh, kVARh,

kVAh, K-Factor, Flicker

Harmonics

1

st

to 50

th

, Direction, Sequence

Power Source

9.6V NiMH rechargeable battery pack (included)

External AC supply: 110/230VAC ±10% (50/60Hz)

Battery Life

≥8 hours with display on; ≤35 hours with display off

(record mode)

MECHANICAL

Communication Port

Optically isolated USB

Display

¼ VGA (320 x 240) color LCD display with adjustable

brightness & contrast

Dimensions

9.8 x 7.8 x 2.6" (250 x 200 x 67mm)

Weight

4.3 lbs (1.95kg)

Safety Rating

EN 61010, 600V CAT IV

(2)

, 1000V CAT III,

Pollution Degree 2

(1)

Crest factor at 6500 = 1

(2)

When used with SR193 or AmpFlex

®

probes.

600V CAT III with MN193 or MR193 probes.

Four voltage and four current inputs

FEATURES

Measurement of TRMS voltages up to 1000Vrms AC/

DC for two-, three-, four- or five-wire systems

Measurement of TRMS currents up to 6500Arms

(sensor dependent)

Direct measurement of neutral current & voltage

Frequency measurement (40 to 69Hz systems)

Record and display trend data as fast as once

per second for one month for up to 25 variables

Transient detection on all V and I inputs (up to 210)

Selectable PT and CT ratios

Inrush current measurement

Calculation of Crest Factors for V and A

Calculation of the K-Factor for transformers

Calculation of short-term flicker and three-phase

voltage unbalance

Measures harmonics (referenced to the fundamental

or RMS value) for voltage, current or power, up to 50

th

harmonic

Displays of harmonic sequencing and

direction and calculation of overall harmonics

Real-time display of Phasor diagrams

including values and phase angles

Measurement of active, reactive and apparent power

per phase and their respective sum total

Calculation of power factor, displacement power factor

and tangent factor

Recording, time stamping and characterization of

disturbance (swells, sags and interruptions,

exceedence of power and harmonic thresholds)

2GB internal Trend Recording memory; Alarm,

Snapshot and Transient/Inrush memories are separate

Measurement of energy VAh, VARh & Wh

The Max and Min RMS measurements are

calculated every half-period

Includes DataView

®

software for configuring

,

real-time

display, analysis and report generation

65μs/sample transient recording

Special

product

features

2G

B

MEMO

R

Y

CA

P

T

RE

TRAN

SI

E

N

TS

TR

E

N

D

RECOR

D

IN

G

''''

NEW!

R ATIN G

SAFETY

IP

Rated

67

cover closed

Advertising