background image

This reliable series of 200 W dc
power supplies can be controlled
either from the front panel or via
an analog programming voltage.
When used in a test system, the fast
up and down programming helps
decrease test time. Quickly reacting
protection features, including fast
crowbar, CV/CC mode crossover and
over-voltage protection help protect
your valuable assemblies from dam-
age. The linear topology produces
very low ripple and noise, which
allows you to make extremely accu-
rate measurements of the devices
which you are testing.

Lab bench use is enhanced by the
fan speed control, which helps to
minimize the acoustic noise.

Agilent Performance dc Power Supplies

speed and accuracy for test optimization

Power Products Catalog 2002-2003

For more detailed specifications see the product manual at

www.agilent.com/find/power

31

Protect valuable assemblies with fast protection features

Proven reliability

Low ripple and noise

6541A-6545A

Single-Output: 200 W

S p e c i f i c a t i o n s

(at 0

˚

to 55

˚

C unless

otherwise specified)

6541A 6542A 6543A 6544A 6545A

Number of outputs

1

1

1

1

1

GPIB

No

No

No

No

No

Output ratings

Output voltage

0 to 8 V

0 to 20 V

0 to 35 V

0 to 60 V

0 to 120 V

Output current (40° C)

0 to 20 A

0 to 10 A

0 to 6 A

0 to 3.5 A

0 to 1.5 A

Maximum current (50° C/55° C)

18 A/17 A

9 A/8.5 A

5.4 A/5.1 A

3.2 A/3 A

1.4 A/1.3 A

Programming accuracy at 25

˚

C ±5

˚

C

Voltage

0.06% +

5 mV

10 mV

15 mV

26 mV

51 mV

Current

0.14% +

26 mA

13 mA

6.7 mA

4.1 mA

1.7 mA

Ripple and noise

from 20 Hz to 20 MHz

Voltage rms

300 µV

300 µV

400 µV

500 µV

700 µV

peak-peak

3 mV

3 mV

4 mV

5 mV

7 mV

Current rms

10 mA

5 mA

3 mA

1.5 mA

1 mA

Load regulation

Voltage

1 mV

2 mV

3 mV

4 mV

5 mV

Current

1 mA

0.5 mA

0.25 mA

0.25 mA

0.25 mA

Line regulation

Voltage

0.5 mV

0.5 mV

1 mV

1mV

2 mV

Current

1 mA

0.5 mA

0.25 mA

0.25 mA

0.25 mA

Transient response time

Less than 100 µs for the output voltage to recover to its previous level
(within 0.1% of the voltage rating of the supply or 20 mV, whichever is greater)
following any step change in load current of up to 50% of rated current

Supplemental Characteristics

(Non-warranted characteristics determined by design and
useful in applying the product)

Average resolution

Voltage

2 mV

5 mV

10 mV

15 mV

30 mV

Current

6 mA

3 mA

2 mA

1.2 mA

0.5 mA

OVP

13 mV

30 mV

54 mV

93 mV

190 mV

OVP accuracy

160 mV

400 mV

700 mV

1.2 V

2.4 V

Advertising