Atec Agilent-6680 Series User Manual

Single-output 5000 w gpib, Specifications

Advertising
background image

Reliable DC power for manufacturing
test and long-term burn-in
This series of 5000 watt DC power
supplies has the exceptional, proven
reliability that test system engineers
look for. It also has the features
needed for easy test system
integration.

Programming of the DC output and
the extensive protection features
can be done either from the front
panel or using industry standard
SCPI commands, via the GPIB.
Using the serial link, up to 16 power
supplies can be connected through
one GPIB address. Test system
integration can be further simplified
by using the VXIPlug&Play drivers.
The output voltage and current
can also be controlled with analog
signals. This is helpful for certain
types of noisy environments, and
also immediate reactions to
process changes.

The 6680A Series has extremely
low ripple and noise for a 5000 watt
DC power supply. This helps the
built-in measurement system make
extremely accurate current and
voltage measurements.

Selectable compensation is provided
for problem-free powering of
inductive loads.

High Performance DC Power Supplies speed and accuracy for test optimization

Specifications

(at 0

˚

to 55

˚

C unless

otherwise specified)

6680A

6681A

6682A

6683A

6684A

6680A-
J04

Special Order
Option

More detailed specifications at www.agilent.com/find/6680

63

Low output ripple and noise

Selectable compensation for inductive loads

Analog control of output voltage and current

Fan-speed control to minimize acoustic noise

Built-in measurements and advanced programmable features

Protection features to ensure DUT safety

6680A-6684A

Single-Output
5000 W GPIB

Number of outputs

1

1

1

1

1

1

GPIB

Yes

Yes

Yes

Yes

Yes

Yes

Output ratings

Voltage

0 to 5 V

0 to 8 V

0 to 21 V

0 to 32 V

0 to 40 V

0 to 3.3 V

Current (40

˚

C then derate linearly

0 to 875 A 0 to 580 A 0 to 240 A 0 to 160 A 0 to 128 A

0 to 1000 A

1%/

˚

C from 40

˚

C to 55

˚

C)

Programming accuracy at 25

˚

C ±5

˚

C

Voltage

0.04% +

5 mV

8 mV

21 mV

32 mV

40 mV

5 mV

Current

0.1% +

450 mA

300 mA

125 mA

85 mA

65 mA

450 mV

Ripple and noise constant voltage mode
from 20 Hz to 20 MHz

rms

1.5 mV

1.5 mV

1.5 mV

1.0 mV

1.0 mV

3.4 mV

Peak to peak

10 mV

10 mV

10 mV

10 mV

10 mV

15 mV

Readback accuracy at 25˚C ±5˚C

(percent of reading plus fixed)

Voltage

0.05% +

7.5 mV

12 mV

32 mV

48 mV

60 mV

7.5 mV

Current

0.1% +

600 mA

400 mA

165 mA

110 mA

90 mA

600 mA

Load and line regulation

Voltage

0.002% +

0.19 mV

0.3 mV

0.65 mV

1.1 mV

1.5 mV

0.19 mV

Current

0.005% +

65 mA

40 mA

17 mA

12 mA

9 mA

77 mA

Transient response time

Less than 900 µs for the output voltage to recover within 150 mV following
a change in load from 100% to 50%, or 50% to 100% of the
output current rating of the supply

Supplemental Characteristics

(Non-warranted characteristics determined by design that are
useful in applying this product)

Ripple and noise constant current mode
from 20 Hz to 20 MHz

rms

290 mA

190 mA

40 mA

28 mA

23 mA

Average programming resolution

Voltage

1.35 mV

2.15 mV

5.7 mV

8.6 mV

10.8 mV

12 mV

Current

235 mA

155 mA

64 mA

43 mA

34 mA

260 mA

OVP

30 mV

45 mV

120 mV

180 mV

225 mV

25 mV

Output voltage programming
response time

9 ms

12 ms

45 ms

60 ms

60 ms

9 ms

(excludes command-processing time) Full-load progrmming rise or fall time (10 to 90% or 90 to 10%, resistive load)

Output common-mode
noise current

rms

1.5 mA

1.5 mA

3 mA

3 mA

3 mA

2.0 mA

(to signal-ground

peak-to-peak

10 mA

10 mA

20 mA

20 mA

20 mA

12.5 mA

binding post)

Note 1: Option 6680A-JO4 is not available outside the USA because certification process is not complete.