Atec Agilent-6670 Series User Manual

Single-output: 2000 w gpib

Advertising
background image

This series of 2000 watt dc power
supplies has the exceptional, proven
reliability that test system engineers
look for. It also has the unusual
combination of high efficiency
and low noise operation.

Programming of the dc output and
the extensive protection features
can be done either from the front
panel or using industry standard
SCPI commands, via the GPIB.
Using the serial link, up to 16 power
supplies can be connected through
one GPIB address. Test system
integration can be further simplified
be using the VXIPlug&Play drivers.
The output voltage and current
can also be controlled with analog
signals. This is helpful for certain
types of noisy environments, and
also immediate reactions to process
changes.

Lab-bench use is enhanced by the
fan-speed control, which minimizes
acoustic noise. The extremely low
ripple and noise helps the built-in
measurement system make extreme-
ly accurate current and voltage
measurements.

Agilent Performance dc Power Supplies

speed and accuracy for test optimization

S p e c i f i c a t i o n s

(at 0

˚

to 55

˚

C unless

otherwise specified)

Power Products Catalog 2002-2003

For more detailed specifications see the product manual at

www.agilent.com/find/power

39

Proven reliability

Increase test throughput with fast up and down programming

High efficiency

Low ripple and noise

6671A - 6675A

Single-Output: 2000 W GPIB

6671A 6672A 6673A 6674A 6675A

Number of outputs

1

1

1

1

1

GPIB

Yes

Yes

Yes

Yes

Yes

Output ratings

Output voltage

0 to 8 V

0 to 20 V

0 to 35 V

0 to 60 V

0 to 120 V

Output current

0 to 220 A

0 to 100 A

0 to 60 A

0 to 35 A

0 to 18 A

Programming accuracy at 25

˚

C ±5

˚

C

Voltage

0.04% +

8 mV

20 mV

35 mV

60 mV

120 mV

Current

0.1% +

125 mA

60 mA

40 mA

25 mA

12 mA

Ripple and noise

from 20 Hz to 20 MHz

Voltage rms

650 µV

750 µV

800 µV

1.25 mV

1.9 mV

Voltage peak to peak

7 mV

9 mV

9 mV

11 mV

16 mV

Current rms

200 mA

100 mA

40 mA

25 mA

12 mA

Readback accuracy at 25˚C ±5˚C
(percent of reading plus fixed)

Voltage

0.05% +

12 mV

30 mV

50 mV

90 mV

180 mV

±Current

0.1% +

150 mA

100 mA

60 mA

35 mA

18 mA

Load regulation

Voltage

0.002%+

300 µV

650 µV

1.2 mV

2 mV

4 mV

Line regulation

Current

0.005%+

10 mA

7 mA

4 mA

2 mA

1 mA

Transient response time

Less than 900 µs for the output voltage to recover 100 mV following a
change in load from 100% to 50% or 50% to 100% of the output current
rating of the supply

Supplemental Characteristics

(Non-warranted characteristics determined by design and
useful in applying the product)

Average resolution

Voltage

2 mV

5 mV

10 mV

15 mV

30 mV

Current

55 mA

25 mA

15 mA

8.75 mA

4.5 mA

OVP

15 mV

35 mV

65 mV

100 mV

215 mV

Output Voltage programming

response time*

(excluding command

30 ms

60 ms

130 ms

130 ms

195 ms

processing time)

*

Full load programming rise/fall time (10% to 90% or 90% to 10%) with full resistive load equal to rated output

voltage/rated output current.

Advertising