Atec Agilent-6030A User Manual

Specifications, Autoranging output

Advertising
background image

This series of 200 watt and 1000
watt DC power supplies take the
place of multiple power supplies
in your test system by providing
maximum power at a variety of
operating points.

Industry standard SCPI commands
and VXIPlug&Play drivers make
system integration easy. Using the
serial link, up to 16 power supplies
can be connected through one
GPIB address. These power supplies
have excellent electrical efficiency,
making them a good choice for
large systems.

Application Notes:

10 Hints for Using Your Power Supply
to Decrease Test Time
5968-6359E

10 Practical Tips You Need to
Know About Your Power Products
5965-8239E

Agilent DC Power Supplies
for Base Station Testing
5988-2386EN

Basic DC Power Supplies essential features for a tight budget

Specifications

(at 0

˚

to 55

˚

C unless

otherwise specified)

6030A 6031A 6032A 6033A 6035A 6038A

More detailed specifications at www.agilent.com/find/6030

25

Autoranging outputs provide maximum power at a variety

of operating voltages

Analog/resistance control of output voltage and current

Series and auto-parallel connections of multiple supplies

Built-in measurements and advanced programmable features

Protection features to ensure DUT safety

6030A, 6031A, 6032A, 6033A, 6035A, 6038A

Single-Output, Autoranging
200 W and 1000 W GPIB

Number of outputs

1

1

1

1

1

1

GPIB

Yes

Yes

Yes

Yes

Yes

Yes

Output ratings

Output Voltage

0 to 200 V 0 to 20 V

0 to 60 V

0 to 20 V

0 to 500 V

0 to 60 V

Output Current

0 to 17 A

0 to 120 A 0 to 50 A

0 to 30 A

0 to 5 A

0 to 10 A

Maximum power watts

1,200 W

1,064 W

1,200 W

242 W

1,050 W

240 W

Autoranging output

V1, I

1

200 V, 5 A

20 V, 50 A

60 V, 17.5 A 20 V, 10 A

500 V, 2 A

60 V, 3.3 A

V2, I

2

120 V, 10 A 14 V, 76 A

40 V, 30 A

14 V, 17.2 A 350 V, 3 A

40 V, 6 A

V3, I

3

60 V, 17 A

7 V, 120 A

20 V, 50 A

6.7 V, 30 A 200 V, 5 A

20 V, 10 A

Programming accuracy

Voltage 0.035% 0.035% 0.035% 0.035% 0.25%

0.035%

at 25°C ±5°C

+145 mV

+15 mV

+40 mV

+9 mV

+400 mV

+40 mV

Current 0.2%

0.25%

0.2%

0.15%

0.3%

0.09%

+25 mA

+250 mA

+85 mA

+20 mA

+63 mA

+10 mA

Ripple and noise

Voltage rms

22 mV

8 mV

8 mV

3 mV

50 mV

3 mV

20 Hz to 20 MHz

p-p

50 mV

50 mV

40 mV

30 mV

160 mV

30 mV

Current rms

15 mA

120 mA

25 mA

30 mA

50 mA

5 mA

Readback accuracy

Voltage 0.08%

0.08%

0.08%

0.07%

0.5%

0.07%

at 25°C ±5°C

+80 mV

+7 mV

+20 mV

+6 mV

+200 mV

+50 mV

Current 0.36%

0.4%

0.36%

0.3%

0.5%

0.2%

+15 mA

+100 mA

+35 mA

+25 mA

+50 mA

+11 mA

Load regulation

Voltage

0.01%+

5 mV

3 mV

5 mV

2 mV

40 mV

3 mV

Current 0.01%+

0.01%+

0.01%+

0.01%+

0.03%+

0.01%+

10 mA

15 mA

10 mA

9 mA

34 mA

5 mA

Line regulation

Voltage 0.01%+

0.01%+

0.01%+

0.01%+

0.03%+

0.01%+

5 mV

2 mV

3 mV

1 mV

17 mV

2 mV

Current 0.01%+

0.01%+

0.01%+

0.01%+

0.03%+

0.01%+

5 mA

25 mA

10 mA

6 mA

17 mA

2 mA

Transient response time

Time

2 ms

2 ms

2 ms

1 ms

5 ms

1 ms

10% step change

Level

150 mV

100 mV

100 mV

50 mV

200 mV 7

5 mV

V1

I1

I2

I3

Volts

P1

P2

P3

Amps

V2
V3

Autoranging Output: