Atec Aeroflex-IFR-3416 User Manual

Page 5

Advertising
background image

Output VSWR

Electronic Attenuator

For output levels < 0 dBm

Frequency

Output VSWR

2 GHz

< 1.25:1

3 GHz

< 1.40:1

4 GHz

< 1.50:1

6 GHz

< 1.60:1

For output levels > 0 dBm VSWR is < 1.5:1 4 GHz, < 1.8:1 6 GHz

Mechanical Attenuator

For output levels < 0 dBm

Frequency

Output VSWR

3 GHz

1.33:1

For output levels > 0 dBm VSWR is < 1.5:1, 3 GHz

No Attenuator

Frequency

Output VSWR

4 GHz

< 1.5:1

6 GHz

< 1.8:1

Attenuator Repeatability

Mechanical attenuator typically 0.1 dB

Output Connector

Front panel 50

type N female to MIL-PRF-39012 class 2

Output Protection

Protects the instrument from externally applied RF power
(from a 50

source) of 50 W up to 3 GHz and 25 W up to 4 GHz

The RPP trip may be reset from the front panel or via the remote inter-
face. For safety, the protection is also provided when the instrument is
switched off.

3416 damage level 0.5 W (+ 27 dBm) from a max 5:1 VSWR, all fre-
quencies

All parameters stated at RF level + 7 dBm in Noise and ACP RF
modes

Harmonics

< -30 dBc, typically < -40 dBc

Sub- and Non-Harmonics

For offsets > 10 kHz
< -70 dBc for carrier frequencies 3 GHz
< -60 dBc for carrier frequencies 6 GHz

Residual FM (FM on CW)

< 2.5 Hz RMS (typically 1.5 Hz) at 1 GHz in a 300 Hz to 3.4 kHz
unweighted bandwidth

SSB Phase Noise

For 20 kHz offset, Noise Optimized mode

CW/IQ

375 MHz

< -115 dBc/Hz

500 MHz

< -124 dBc/Hz

1 GHz

< -118 dBc/Hz

2 GHz

< -112 dBc/Hz

3 GHz

< -108 dBc/Hz

4 GHz

< -106 dBc/Hz

6 GHz

< -102 dBc/Hz

Advertising