Spectrum Analyzer Specifications

MS2720T TDS

PN: 11410-00646 Rev. H

3 of 24

Spectrum Analyzer

(continued)

Spectral Purity – SSB Phase Noise at 1 GHz

Amplitude Ranges

Dynamic Range

>106 dB minimum at 2.4 GHz, 2/3 (TOI-DANL) in 1 Hz RBW

Measurement Range

DANL to +30 dBm

Display Range

1 to 15 dB/div in 1 dB steps, ten divisions displayed

Reference Level Range

–120 dBm to +30 dBm

Attenuator Resolution

0 to 65 dB, 5.0 dB steps

Amplitude Units

Log Scale Modes: dBm, dBV, dBmV, dBμV
Linear Scale Modes: nV, μV, mV, V, kV, nW, μW, mW, W, kW

Maximum Continuous Input

+30 dBm Peak typical, ± 50 VDC (≥ 10 dB Attenuation)
+23 dBm Peak typical, ± 50 VDC (< 10 dB Attenuation)
+13 dBm Peak typical, ± 50 VDC (Preamp = ON)

Amplitude Accuracy

Displayed Average Noise Level (DANL)

(RMS detection, VBW/Avg type = Log, Ref Level = –20 dBm for Preamp Off and –50 dBm for

Preamp On, Performance Sweep Mode)

Spurs

Offset

9 GHz Instrument

13 GHz to 43 GHz Instruments

10 kHz

100 kHz

1 MHz

10 MHz

Maximum

–108 dBc/Hz
–110 dBc/Hz
–118 dBc/Hz
–129 dBc/Hz

Typical

–112 dBc/Hz
–115 dBc/Hz
–123 dBc/Hz
–133 dBc/Hz

Maximum

–102 dBc/Hz
–106 dBc/Hz
–111 dBc/Hz
–123 dBc/Hz

Typical

–106 dBc/Hz
–110 dBc/Hz
–116 dBc/Hz
–129 dBc/Hz

20 °C to 30 °C

(after 30 minute warm-up)

–10 °C to 55 °C

(after 60 minute warm-up)

9 GHz Instrument

9 kHz to 100 kHz

a

100 kHz to 7 GHz

> 7 GHz to 9 GHz

a. Values below 100 kHz are with the preamplifier turned off.

Maximum

± 1.3 dB
± 1.8 dB

Typical

± 1.0 dB
± 0.5 dB
± 0.5 dB

Maximum

± 2.3 dB
± 2.8 dB

Typical

± 1.0 dB
± 0.5 dB
± 0.5 dB

20 GHz Instruments

100 kHz to 13 GHz

> 13 GHz to 18 GHz
> 18 GHz to 20 GHz

± 1.3 dB
± 2.3 dB

± 0.5 dB
± 0.5 dB
± 1.0 dB

± 2.3 dB
± 3.3 dB

± 05 dB

± 0.5 dB
± 1.0 dB

43 GHz Instruments

> 100 kHz to 13 GHz

> 13 GHz to 40 GHz
> 40 GHz to 43 GHz

± 1.3 dB
± 2.3 dB

± 0.5 dB
± 0.5 dB
± 1.0 dB

± 2.3 dB
± 3.3 dB

± 0.5 dB
± 0.5 dB
± 1.0 dB

Preamp = Off

Preamp = On

9 GHz Instrument

10 MHz to 3 GHz

> 3 GHz to 8 GHz
> 8 GHz to 9 GHz

Maximum

–146 dBm
–140 dBm

Typical

–149 dBm
–143 dBm
–142 dBm

Maximum

–160 dBm
–152 dBm

Typical

–163 dBm
–155 dBm
–155 dBm

13 to 43 GHz Instruments

10 MHz to 4 GHz

> 4 GHz to 9 GHz

> 9 GHz to 13 GHz

–145 dBm
–142 dBm
–136 dBm

–148 dBm
–145 dBm
–139 dBm

–161 dBm
–159 dBm
–156 dBm

–164 dBm
–162 dBm
–159 dBm

20 GHz Instrument

> 13 GHz to 20 GHz

–138 dBm

–141 dBm

–157 dBm

–160 dBm

32 to 43 GHz Instruments

> 13 GHz to 32 GHz
> 32 GHz to 40 GHz
> 40 GHz to 43 GHz

–135 dBm
–127 dBm

–138 dBm
–130 dBm
–130 dBm

–154 dBm
–148 dBm

–157 dBm
–151 dBm
–151 dBm

(RF input terminated, 0 dB input attenuation)

Residual Spurs

< 13 GHz

13 to 20 GHz

> 20 to 32 GHz
> 32 to 43 GHz

Preamp = Off

–90 dBm, maximum
–85 dBm, maximum
–80 dBm, maximum
–80 dBm, maximum

Preamp = On

–100 dBm, maximum
–100 dBm, maximum
–100 dBm, maximum

–95 dBm, maximum

Input-Related Spurious

–60 dBc, –70 dBc typical (0 dB attenuation, –30 dBm input, span < 1.7 GHz)