Atec Acterna-JDSU-SDA-5000 User Manual

Page 9

Advertising
background image

Specifications

Frequency

Range

5 to 1000 MHz

Accuracy

±10 ppm at 25°C;

±10 ppm drift over temp

±3 ppm/year aging

Resolution bandwidths

30, 280 kHz and 2 MHz

(30 kHz for CTB/CSO only)

Tuning resolution

10 kHz

Sweep resolution

250 kHz maximum

Level measurement

Range

40 to +60 dBmV

Resolution

0.1 dB

Accuracy

±1.0 dB from 20 to +50°C

(1,2)

Log linearity

±0.5 dB

(1)

Flatness

±0.5 dB

(3)

Signal types

CW, single carrier, video

(single or dual audio/NICAM), audio, digital

Uncertainty for digital carrier

additional ±0.5 dB (digital types 16/32/64/256

QAM, QPR, QPSK, VSB, CAP-16, DVB/ACTS and

TDMA using Zero Span Spectrum mode)

at 280 kHz RBW

Carrier-to-noise

(4)

In-service measurement. Non-scrambled channels
only. No preselection required for 78 channels
or less. Best dynamic range at +10 dBmV or
higher input.
Range

≥ 52 dB

(1)

Resolution

< 0.5 dB

Hum measurement

In-service measurement. Carrier > 0 dBmV.
Non-scrambled channels only.
Range

0 to 10%

Resolution

< 0.2%

Accuracy

±0.7%

Depth of modulation

Assumes presence of white reference on any VITS
line. Non-scrambled channels only.
Audio demodulation of AM and FM carriers.
Range

80 to 100%

Resolution

< 0.5% at 85%

Audio demodulation

AM and FM Carriers

Tilt measurement

Up to nine pilot carriers or video channels with tilt
and level measurements on the highest and lowest.
Hi-lo

∆ resolution

0.1 dB

Scan mode

All video, audio, pilot carrier, and digital channel
levels displayed.

9

A

or

B

SAM-4040D

SAM-4040

SDA-4040D

QAM view option

A

or

B

SSA-1000

3SR

SDA-5000

QAM view option

3ST

3HRV

SDA-5500

SDA-5510

Start with any
SAM-4040 or 4040D

Optional:

PathTrak Field View (4040D)

A) Firmware
B) Hardware & Firmware

Upgrade to SDA-4040D
Standard:

Optional:

DigiCheck

PathTrak

ZeroSpan

Field View

Dig Spectrum

Add Option 4 for: QAM View

Any Stealth can upgrade to
SDA-5000 for:
5 x faster sweep
256 QAM compatible sweep
Improved TP Comp setup
for reverse sweep
A) Firmware
B) Hardware & Firmware

SDA-5000 units can be
purchased with, or upgraded to:
QAM View
PathTrak Field View

Any 3ST can be upgraded to
SDA-5000 for faster forward
sweep and digital signal
sweep compatibility

Any 3HRV can be upgraded
to SDA-5510

Stealth to SDA series – product upgrade/replacement guide

Stealth model

SDA replacement

3SR

SDA-5000

3SR + 3SRV option

SDA-5000 with Option 1

3SR + 3SRT option

SDA-5000 with Option 2

3ST SDA-5500
3HRV

SDA-5510

SSA-1000

SDA-5000 with Option 2 (Firmware only)

SAM 4040

SDA-4040D

SAM-4040D

SDA-4040D (Firmware only)

Advertising