JD788A

CellAdvisor™ Signal Analyzer

Spectrum Analyzer: 9 kHz to 8 GHz

Power Meter: 10 MHz to 8 GHz

Specification* Conditions

The JD788A specifications apply under these conditions:
• The instrument has been turned on for at least 15 minutes

• The instrument is operating within a valid calibration period

• Data with no tolerance are considered typical values

• Cable and antenna measurements apply after calibration to the OSL standard

• Typical and nominal values are defined as:

Typical: expected performance of the instrument operating under 20° to 30°C

after being at this temperature for 15 minutes

Nominal: a general, descriptive term or parameter

Spectrum Analyzer (Standard)

Frequency

Frequency range

9 kHz to 8 GHz

Internal 10 MHz Frequency Reference

Accuracy

±0.05 ppm + aging (0 to 50°C)

Aging

±0.5 ppm/year

Frequency Span

Range

0 Hz (zero span)
10 Hz to 8 GHz

Resolution

1 Hz

Resolution Bandwidth (RBW)

–3 dB bandwidth

1 Hz to 3 MHz

1-3-10 sequence

Accuracy

±10% (nominal)

Video Bandwidth (VBW)

–3 dB bandwidth

1 Hz to 3 MHz

1-3-10 sequence

Accuracy

±10% (nominal)

Single Sideband (SSB) Phase Noise

Fc 1 GHz, RBW 10 kHz, VBW 1 kHz, RMS detector
Carrier offset:
30 kHz
100 kHz
1 MHz

–100 dBc/Hz (–102 dBc/Hz, typical)
–105 dBc/Hz (–112 dBc/Hz, typical)
–115 dBc/Hz (–120 dBc/Hz, typical)

Measurement Range

DANL to +25 dBm

Input attenuator range

0 to 55 dB, 5 dB steps

Maximum Input Level

Average continuous power

+25 dBm

DC voltage

±50 VDC

*All specifications are subject to change without notice.