Avionics

MLS-800

Microprocessor Controlled Ground Station Simulator

Test Operational Menu supports ICAO
1985 and EUROCAE ED-53A and
ED-36A

Complete Main Path Simulation:
Approach (AZ) and High Rate Azimuth
(HiAZ) Elevation (EL) Back Azimuth (BAZ)
Flare (FL)

Complete Multi-path (MP) Simulation
Capability:
Interference Pulses
Selectable Fade Rate Modulation of 0.05,
1 and 1000 Hz

Control of all Beam Parameters:
Angular Position Beam Amplitude
Referenced to the Preamble Norm and
Half Width Pulse Selectable Beam Width
at 0.5°, 1°, 2°, 3°, 4° or 5°

Sync Capability for: External Monitoring
Designating PFE and CMN Function
Designating Multi-path Function

Preamble Parity, Symmetry and Percent
Update

Simulates all Basic Data Words plus
Auxiliary Data Words with Parity Selection

Full Range of MLS Channels

Aeroflex is a leader in the design, manufacture

and marketing of Avionics test systems.

The MLS-800 is a microprocessor controlled Ground Station
Simulator designed to operate from a bench test environment. Test
parameters are selected via a 44-position keyboard and displayed on
test operational menus.

Other Features

• OCI Control for Right (RT), Left (LT) and Rear (RR)

• 75 dB AZ to EL Ratio Capability Propellor/Rotor Modulation at 1

to 100 Hz Variable in 1 Hz steps Morse Code Identification
Capability

• ARINC 429 Receiver with PFE and CMN calculations

• External RF Reference Input

• Clearance Pulse Simulation

• 6.75 Hz Modulation

• IEEE-488-1978 Interface for Remote Control Operation

S

SP

PE

EC

CIIF

FIIC

CA

AT

TIIO

ON

N

G

GE

EN

NE

ER

RA

AL

L R

RE

EQ

QU

UIIR

RE

EM

ME

EN

NT

TS

S

Unless otherwise noted the following equipment performance char-

acteristics are warranted over the specified environmental conditions
following a 20 minute warm-up period.

All RF measurements are referenced to 50 Ω.
Accuracy and resolution stated in percent are referenced to measured

or desired values.

Where resolution exceeds accuracy, resolution takes precedence.
Notes are intended to provide information useful in applying the

instrument by giving specific setup information. Notes are found in
the notes section of this specification.

Advertising